![Navien NCB-150E Скачать руководство пользователя страница 77](http://html2.mh-extra.com/html/navien/ncb-150e/ncb-150e_service-manual_3623910077.webp)
Version 1.4
76 NCB-E Service Manual
4.9.13 DHW Heat Exchanger
Part
Check Point
Function
Water heated in the primary/secondary heat exchanger is circulated to the plate heat exchanger,
where the heat of heating water and tap water are exchanged so that hot water is available
Failure Event
1. Water leakage through a crack.
2. Improper heat transfer can cause the cold water in heat exchanger
Effects
Temperature fluctuations in the hot water outlet and/or leaking.
Error Code
E016, E030, E353
Diagnostic
The plate heat exchanger filters out impurities in space heating pipes to prevent heating problems
caused by impurities.
Leak in plate heat exchanger will cause pressure in space heating side to increase to tap water
pressure level.