![Navien NCB-150E Скачать руководство пользователя страница 106](http://html2.mh-extra.com/html/navien/ncb-150e/ncb-150e_service-manual_3623910106.webp)
Troubleshooting 105
5.2.7 046Error
Error occurrence conditions and check items
Is heat exchanger
thermistor normally
operating?
Is resistance
within normal range?
(refer to page 66)
Replace heat exchanger
thermistor.
Check connector
( #3 and #4 of CN 13)
1 step: Flushing, Clean Filter
2 step: Try to restart
3 step: Replace PCB
Yes
Yes
No
No
5.2.8 047Error
Error occurrence conditions and check items
Is exhaust thermistor
operating normally?
Check connector
(#9 and #10 of CN13)
Replace exhaust thermistor
Resistance between #9 and #10 of CN13
is from 2kΩ to 300kΩ at normal condition.
(see page 60 for Wiring Diagram)
No
Yes
Содержание NCB-150E
Страница 3: ......
Страница 147: ...Version 1 4 146 NCB E Service Manual 7 2 Burner Assembly 1 2 9 10 11 12 13 14 21 18 17 4 20 13 19 12 10 16 15 3 6 5 7 8...
Страница 153: ...Version 1 4 152 NCB E Service Manual 7 5 Fan Gas Assembly 2 4 7 5 6 11 14 12 11 10 9 13 11 15 1 3 8...
Страница 156: ...Memo...
Страница 157: ...Memo...