![Navien NCB-150E Скачать руководство пользователя страница 65](http://html2.mh-extra.com/html/navien/ncb-150e/ncb-150e_service-manual_3623910065.webp)
Version 1.4
64 NCB-E Service Manual
4.9 Key Components Description
4.9.1 PCB
Part
Check Point
Function
To control each component and also to check the overall performance of the unit.
Failure Event
Malfunctioning PCB.
Effects
A component may not operate within the unit and could produce an error code. In most cases of
PCB failure, the whole unit will not operate until the problem is resolved.
Error Code
E515, E615
Diagnostic
Visual inspection: Connection and/or breakage of wires and/or burn marks on the PCB.
Color/Number of wires
Refer to page 60-63