![Nautel NX400 Скачать руководство пользователя страница 66](http://html2.mh-extra.com/html/nautel/nx400/nx400_installation-manual_3574073066.webp)
NX400 Installation Manual
Commissioning tasks
Issue 1.0 2017-06-30
Page 10-3
Commissioning
Turning on the transmitter
1. Switch on the ac power at the service entrance to turn on the transmitter.
2. Check the alarm and status indications on the control cabinet’s AUI using the
Transmitter
Status
page of the AUI. See the
NX400
Operations & Maintenance Manual or the
NX400
Troubleshooting Manual for detailed information.
NOTE
: It is normal to see an "
External Inhibit Active
" alarm from each exciter as well as an
"
Interlock Open
" alarm (if the test load interlock is not closed) at this stage.
3. Check the output of the +5, +15 and -15 V power supplies on the AUI (click
Meters
, then
select
Rack 1
and the appropriate power supply). Each power supply voltage should be within
+/- 10% of its nominal voltage.
4. Check the ac sample voltage on the AUI (click
Meters
, then select
Rack 1
and then select AC
Sample). It should be between 310 V and 335 V. If not, change the transformer tap setting
(see
Section 4, “Connecting transformer taps/load wiring”
). If the ac sample voltage is too
high, you will need to increase the tap voltage. If the ac sample voltage is too low, you will
need to decrease the tap voltage.
5. Disable remote control (the Remote indicator should be blue).
6. Set the active preset’s power output to 40,000 W as follows:
•
Go to the AUI’s
Menu
->
Presets
page. Press the
Load
button on the left side of the
Presets
page to display a window containing a list of other presets. Select the “Analog”
preset and press
OK
.
•
In the preset’s
Output Power
field, enter 40 kW and press
Save
.
•
In the
Transmitter
block in the AUI’s top banner, press the bar that contains the active
preset name and the drop-down arrow. The
Activate Preset
window will appear, which
contains a list of all preset options. Select the “Analog” preset and press
Activate
to
enable the preset as the transmitter’s active preset.
Note:
The following procedures require the use of the transmitter’s front panel AUI. If you require
assistance to navigate the front panel, refer to the NX400 Operations and Maintenance Manual
for detailed information.
Содержание NX400
Страница 1: ...NX400 Transmitter Installation Manual Document NHB NX400 INS Issue 1 0 2017 06 30 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX400 Installation Manual Page x Issue 1 0 2017 06 30...
Страница 12: ...NX400 Installation Manual Preparing for installation Page 1 4 Issue 1 0 2017 06 30...
Страница 22: ...NX400 Installation Manual Unpacking and positioning Page 2 10 Issue 1 0 2017 06 30...
Страница 43: ...NX400 Installation Manual Connecting transformer taps and secondary wiring Page 4 8 Issue 1 0 2017 06 30...
Страница 49: ...NX400 Installation Manual Connecting ac power Page 6 4 Issue 1 0 2017 06 30...
Страница 53: ...NX400 Installation Manual Adjusting the spark gap Page 7 4 Issue 1 0 2017 06 30...
Страница 75: ...NX400 Installation Manual Parts and tools Page 11 4 Issue 1 0 2017 06 30...
Страница 85: ...NX400 Installation Manual Pre installation Installation assistance Page 12 10 Issue 1 0 2017 06 30...
Страница 88: ......