Adjusting the spark gap
Issue 1.0 2017-06-30
Page 7-1
Section 7:
Adjusting the spark gap
The NX400’s RF output filter contains a spark gap that must be adjusted - based on site altitude - to
provide protection against excessive voltage (i.e., lightning) on the RF output.
NOTE
:
Nautel presets the spark gap for 0.417 inches, which corresponds to a site altitude of 0 m (i.e,
sea level). If your transmitter site is at sea level, no spark gap adjustment is required.
1. Determine the altitude of the transmitter site (in feet).
2. Make sure that the ac power is switched off and locked out. Refer to the Operating section of
the
NX400 Operations and Maintenance Manual
for instructions on using the ac disconnect
switch, which is provided by Nautel.
3. Gain access to the RF output spark gap, by opening the front door of the output cabinet
(cabinet 3) and then opening the hinged filter panel, noting that it is secured using 23 M5
screws. Retain hardware.
4. Locate the spark gap (see
). Using a feeler gauge, measure the air gap
between the spark gap balls.
5. The air gap should be 0.417 inches multiplied by the scale factor listed in
for the altitude determined in
. If not, loosen the locking nut
on the bottom carbon hemisphere, adjust the position of the spark gap ball for the required
gap and then tighten the locking nut.
6. Close and secure the filter door using M5 screws
retained from
WARNING:
THE AC VOLTAGES PRESENT IN THE TRANSMITTER CAN BE FATAL. EXERCISE
EXTREME CAUTION.
Содержание NX400
Страница 1: ...NX400 Transmitter Installation Manual Document NHB NX400 INS Issue 1 0 2017 06 30 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX400 Installation Manual Page x Issue 1 0 2017 06 30...
Страница 12: ...NX400 Installation Manual Preparing for installation Page 1 4 Issue 1 0 2017 06 30...
Страница 22: ...NX400 Installation Manual Unpacking and positioning Page 2 10 Issue 1 0 2017 06 30...
Страница 43: ...NX400 Installation Manual Connecting transformer taps and secondary wiring Page 4 8 Issue 1 0 2017 06 30...
Страница 49: ...NX400 Installation Manual Connecting ac power Page 6 4 Issue 1 0 2017 06 30...
Страница 53: ...NX400 Installation Manual Adjusting the spark gap Page 7 4 Issue 1 0 2017 06 30...
Страница 75: ...NX400 Installation Manual Parts and tools Page 11 4 Issue 1 0 2017 06 30...
Страница 85: ...NX400 Installation Manual Pre installation Installation assistance Page 12 10 Issue 1 0 2017 06 30...
Страница 88: ......