Table 7.1: Station Interface Connector Digital I/O
Signal
Direction (Level)
Function
Pin
Not Used
Input (Open/Ground)
-
1
Diversity Delay
Ramp Up
Input (Open/Ground)
Ramps up diversity delay when ground is applied.
3
Diversity Delay
Ramp Down
Input (Open/Ground)
Ramps down diversity delay when ground is applied.
4
Diversity Delay
Increase
Input (Open/Ground)
Increases diversity delay by the amount set in the UI (see
“Setting Delay Increment”) when ground is applied.
5
Diversity Delay
Decrease
Input (Open/Ground)
Decreases diversity delay by the amount set in the UI (see
“Setting Delay Increment”) when ground is applied.
6
Audio Bypass On/
Off
Input (Open/Ground)
Bypasses analog audio when ground is applied.
7
1PPS Out
Output (3.3 V/Ground)
Passes through interface card from Exporter PCI card.
10
Watchdog Disable
Input (Open/Ground)
Application watchdog is disabled when ground is applied.
11
Power On/Off
Input (Open/Ground)
Power switches off when ground is applied and on when
changed from ground to open circuit.
12
Ramp Status
Output (Open/Ground)
Ground potential (0 V) when the target ramp state has been
set to ‘up’. Open circuit when the target ramp state has been
set to ‘down’.
15
Delay Inc/Dec
Output (Open/Ground)
Ground potential (0 V) when analog audio is ramping up or
down. Open circuit when it is not ramping up or down.
16
Bypass Status
Output (Open/Ground)
Ground potential (0 V) when analog audio is being bypassed.
Open circuit when it is not being bypassed.
17
1 PPS In
Input (3.3 V/Ground)
Passes through interface card to Exporter PCI card.
18
Shutdown Status
Output (Open/Ground)
Ground potential (0 V) when the Exporter Plus is shutting
down. Open circuit during normal operation.
19
Operational Status Output (Open/Ground)
Ground potential (0 V) when the Exporter Plus is operational
(
Status
LED is green or orange) . Open circuit when non-
operational.
20
Alarm Status
Output (Open/Ground)
Ground potential (0 V) when an alarm (
Status
LED red) or
warning (
Status
LED orange) is active. Open circuit when e
no active alarms or warnings. Along with pin 20, can
22
Common
-
-
25
Содержание Exporter Plus
Страница 2: ......
Страница 4: ......
Страница 8: ...Exporter Plus Technical Instruction Manual Table of contents Page viii Issue 1 0 2020 05 05...
Страница 26: ...Exporter Plus Technical Instruction Manual Pre installation tasks Page 2 4 Issue 1 0 2020 05 05...
Страница 28: ...Exporter Plus Technical Instruction Manual Parts and tools Page 3 2 Issue 1 0 2020 05 05...
Страница 30: ...Exporter Plus Technical Instruction Manual Unpacking Page 4 2 Issue 1 0 2020 05 05...
Страница 34: ......
Страница 36: ......
Страница 38: ......
Страница 164: ...Exporter Plus Technical Instruction Manual Operating Page 8 94 Issue 1 0 2020 05 05...
Страница 166: ...Exporter Plus Technical Instruction Manual Routine maintenance Page 9 2 Issue 1 0 2020 05 05...
Страница 180: ...Exporter Plus Technical Instruction Manual Troubleshooting Page 10 14 Issue 1 0 2020 05 05...
Страница 182: ......
Страница 185: ......