SPECIFICATIONS
GEM-P3200
Panel Dimensions: 12 3/8" x 13 7/8" x 3 ½" (H x W x D) without cover
Operating Temperature: 0-49°C (32-120°F)
Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer
Loop Voltage: 10-13VDC
Loop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4
mA using a 3.9K Ohm resistor (Model EOL 3.9K) with Zone Doubling
Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones
Relay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring Dia-
gram), SPDT contacts 24Vdc, 2A, 0.6 PF
Auxiliary Power Output: 12Vdc regulated
Remote Power Output: 12Vdc regulated (for keypads)
Combined Standby Current (Remote Power + Aux. Power + Reset Relay Power): See following charts.
Note:
(1)
With 1 RBAT6 battery, GEM-P3200 combined standby c PS3002 standby current may not exceed 1.2A.
(2)
W(2) With 2 RBAT6 batteries, GEM-P3200 combined standby c alarm current may not exceed 1.9A.
Standby Time: Residential Fire/Burglary & Commercial Burglary, 4 hours minimum
EZM Module: GEM-EZM8: Input, 50mA (not including PGM output)
PGM Output: 5mA, 12V Special Application
Keypad Current:
GEM-RP1CAe2/GEM-K1CA: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3)
GEM-RP2ASe2/GEM-K2AS: 50 mA
GEM-RP3DGTL/GEM-K3DGTL: 50 mA
GEM-RP4RFC/GEM-K4RF: 75mA Standby
GEM-RP4C/GEM-K4: 45mA Standby
PGM Output: 5mA, 12V Special Application
Maximum Number of Keypads: 7
Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on run
Keypad Dimensions: 4 ¼" x 5 ¾" x 1" (H x W x D); 11.1cm
ORDERING INFORMATION
System Components
GEM-P3200: Residential UL-Listed Burg Control Panel.
GEM-RP1CAe2/GEM-K1CA: 32-Character LCD Burg & Residential Fire Keypad with 4 EOL resistor supervised Zones.
GEM-RP2ASe2/GEM-K2AS: LCD Burg & Residential Fire Keypad with remote panic.
GEM-RP3DGTL/GEM-K3DGTL: Digital Burg and Residential Fire Keypad with remote panic.
GEM-RP4RFC/GEM-K4RF: Digital Icon Burg and Residential Fire Keypad with Integral RF Receiver.
GEM-RP4C/GEM-K4: Digital Icon Burg and Residential Fire Keypad.
TRANSFORMER
RECHARGEABLE
BATTERY
POWER
SUPPLY
GEM-P3200 COM-
BINED
STANDBY CURRENT
GEM-P3200
ALARM
CURRENT
POWER SUPPLY
STANDBY
CURRENT
STANDBY
TIME
TRF11 (16.5 VAC, 40 VA)
RBAT4 (12 VDC, 4 AH)
N/A
750 mA
2.0 A
N/A
4 Hours
TRF11 (16.5 VAC, 40 VA)
RBAT6 (12 VDC, 6 AH)
N/A
750 mA
2.0 A
N/A
6 Hours
TRF11 (16.5 VAC, 40 VA)
(3)
RBAT6 (12 VDC, 6 AH)
PS3002 (13.2 VDC, 1.9 A)
750 mA
(1)
1.9 A
(2)
1.2 A
(1,2)
4 Hours
TRF11 (16.5 VAC, 40 VA)
(3)
2 RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A)
750 mA
1.9 A
1.4 A
4 Hours
RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY
TRANSFORMER
RECHARGEABLE
BATTERY
GEM-P3200
COMBINED
STANDBY CURRENT
GEM-P3200
ALARM
CURRENT
STANDBY
TIME
TRF11 (16.5 VAC, 40 VA)
RBAT7 (12 VDC, 7 AH)
150 mA
650 mA
24 Hours
RESIDENTIAL FIRE, COMBINATION RESIDENTIAL FIRE & BURGLARY
Содержание Gemini GEM-P3200
Страница 58: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 58 NOTES...
Страница 60: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 60 GEM P3200 WIRING DIAGRAM...
Страница 66: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 66 Notes...
Страница 67: ...L NAPCO Security Systems X GEM P3200 Installation Instructions WI817F 10 05 Page 67 Notes...