  GEM-P3200 Installation Instructions 

L

 NAPCO Security Systems 

WI817F  10/05 

 

Page 40

 

Entry delay may be canceled by pressing and holding the 

P

 button prior to arming, however it will be restored automatically 

upon disarming.  (When armed with Instant protection, an “I” will appear at the right side of the display.) 

 

Exit/Entry Follower 

A zone programmed as an Exit/Entry Follower will ignore detection during the exit delay, and only during entry delay if the Exit/

Entry Zone is entered first.  Thus, detection devices (passive infrared detectors, for example) along the path between the keypad and 
the exit/entry door will not signal an alarm during exit/entry delay under normal conditions.  However, if a device in the Exit/Entry Fol-
lower Zone detects a violation when the exit/entry door has not first been entered, there will be no entry delay and the Exit/Entry Fol-
lower Zone will go into an instant alarm. 

If the panel is armed with the entry delays canceled (Instant protection), any violation on the Exit/Entry Zone or the Exit/Entry Fol-

lower Zone will cause an immediate alarm. 

 

Expansion Zones 
EZM Type 
EZM PGM Armed Terminal Control 
EZM Tamper

   See Tamper 

Zones 9–32 are expansion zones added to the basic system using expansion zone modules (EZMs).  Any combination of GEM-

EZM4 (4 zones), GEM-EZM8 (8 zones) and/or the 4-zone modules integral to each GEM-RP1CAe2 and GEM-K1CA keypads may be 
used.  Refer to Section 2:  ADDING EXPANSION ZONES and the Wiring Diagram.  Also see the instructions accompanying each 
module for wiring information. 

Regardless of how the modules are arranged, the expansion zones are divided into consecutively-numbered groups of four.  

Each 4-zone module comprises one group of zones; each 8-zone module comprises two groups.  Each group is assigned a number. 

For each EZM group, program EZM Type (two nibbles, left and right), as follows:  EZM Not Used:  leave both nibbles blank (); 

Burglary EZM:  enter “1” in the right nibble (1). 

If EZM PGM Armed Terminal Control is programmed for the EZM module, Terminal 6 on the module will go low when the areas 

programmed for that module are armed.  This may be used to display area-armed status (for example) on an external LED.  

Note:  

(1) This terminal is intended for connection to UL-listed devices rated 5mA maximum and capable of operating from 8.0–13.0Vdc 
(12V, special application).  (2) In two-group modules (GEM-EZM8), only the lower of the two groups may be programmed. 

 

Extended Format

   See Data Format 

 

Fire 
Keypad Fire 

Any zone may be programmed for Fire.  Connect normally-open devices across a Fire Zone.  The EOL2.2K end-of-line resistor 

must be installed (4-wire smoke detectors require an FT2200 relay instead of a resistor to supervise the power to the detector).  A 
short across the zone will cause a fire alarm, which will be indicated at the keypad by a “

FIRE

”  LCD display and pulsing sounder.  An 

open circuit on the Fire Zone will identify a trouble and cause flashing “

FIRE

” LCD display and pulsing sounder after a 10-second delay.  

The sounder may be silenced using the 

C

 button.  The LED will go off within 30 seconds after reset if the alarm or trouble is 

cleared.  For Smoke-Detector Reset, see Alarm Outputs. 

A fire condition that has not been restored will cause the zone number and description to scroll.  To reset (acknowledge) the con-

dition, enter a valid code, then press the 

C

 button. 

If Keypad Fire is programmed, pressing both the 

7

 and the 

G

 keypad buttons at the same time will sound a fire panic 

alarm and display “

***FIRE ALARM***

” at the keypad.  The Keypad Fire function is supplementary to the hardwired zones.  

Note:  

This 

feature shall not be considered a substitute for listed manual initiating devices. 

 

Fire Verification (Not for use in California.) 

Fire Zone programmed for “Fire Alarm Verification” will cause all zones to power down for 12 seconds.  (All devices must be 

wired with + power on Terminal 28).  After this time, power is restored and a 4-second power-up time is started.  Thereafter, the zone 
will be active again.  This represents a total processing delay of 16 seconds from the time the alarm is first detected.  If an alarm con-
dition still exists at this time or reoccurs within 2 minutes, an alarm will be initiated, otherwise the zone will return to its original state.  

NOTE:  

A zone programmed for “Fire Alarm Verification” must be programmed as a “Fire Zone” as well. 

 

Fire Output

 (Lug E9) 

Lug E9 (FIRE) will go to about 1Vdc when a Fire Zone programmed for Fire Output is tripped.  This lug may be used for auxiliary 

equipment.  (For use, refer to the instructions furnished with the device).  Use Napco Part No.  WL1 for connection. 

 

Global System Troubles by Output 

System troubles (Low Battery, AC Failure, etc.) can trip any output (Pulsed Burg, Auxiliary, etc.).  

Note:  

RF TROUBLE will report 

for RF Low Battery, RF Supervisory Failure or GEM-DT Self-Test Failure. 

 

Interior Stay Zones; Interior 1 Normally Bypassed; Automatic Interior Bypass/Easy Exit 

(Applies to "GEM-RP" keypads only).  Removal of a programmed group of interior (Stay) zones from the system will permit freedom 
of movement throughout the premises but still allow protection from intrusion through armed perimeter zones.  Pressing 

E

 prior 

to arming will select the Interior Zones, then arm to bypass.  The next time the control panel is disarmed, all bypassed zones will 
automatically revert to non-bypassed (disarmed) zones.  When 

E

 is pressed, the “

BYPASS

” reminder will come on. 

The bypassed zones may be displayed on the keypad (see GEM-RP1CAe2/GEM-K1CA FUNCTION MODE). 
If Interior Normally Bypassed is selected, all Interior (STAY) Zones will always be inactive. The “

BYPASS

” reminder will always display, 

GLOSS

A

RY

 

Содержание Gemini GEM-P3200

Страница 1: ...RP3DGTL and GEM RP4RFC GEM RP4C and with K Series keypads GEM K1CA GEM K2AS GEM K3DGTL and GEM K4RF GEM K4 Publicly traded on NASDAQ Symbol NSSC K Series GEM K1CA G E M I N I SYSTEM READY 01 01 06 12...

Страница 2: ...ol panel zones 7 8 Page 18 also removed the incorrect wiring diagram and accompanying text THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL FIRM WARE VERSION 50 OR LATER NAPCO S...

Страница 3: ...oth keypads The words NEXT YES button are used in this manual The button and the button operate identically in Program Mode for both keypads The words PRIOR NO button are used in this manual For consi...

Страница 4: ...figuration 16 4 Wire Smoke Detectors 17 2 Wire Smoke Detectors 17 Telephone Lines 18 KEYPAD CONFIGURATION MODE 19 Keypad Installation 19 Configuring the Keypads 19 BASIC OPERATION 22 User Codes Zone D...

Страница 5: ...downloaded to the control panel using a PC compatible computer with NAPCO s PCD Windows Quickloader software and a PCI2000 computer interface Or the panel may be programmed using the keypad in its sec...

Страница 6: ...ID Rotary dial TouchToneTM only and TouchToneTM with Rotary backup Three 20 digit telephone numbers Backup Reporting Double Reporting Split Reporting 48 User Codes with Open Close Reporting by user AC...

Страница 7: ...EM RP3DGTL GEM K3DGTL 50 mA GEM RP4RFC GEM K4RF 75mA Standby GEM RP4C GEM K4 45mA Standby PGM Output 5mA 12V Special Application Maximum Number of Keypads 7 Maximum Wiring Length for each run 22AWG 10...

Страница 8: ...le plug in 20 OI193 User Guide GEM RP1CAe2 OI192 User Guide GEM RP2ASe2 OI249 User Guide GEM RP3DGTL OI278 User Guide GEM RP4C RP4RFC WI1212 Installation Manual GEM RP4C WI1128 Installation Manual GEM...

Страница 9: ...rogrammed for Priority Do not program any zones for Keyswitch Arming System must be serviced at least once every year Residential Fire and Combination Residential Fire Burglary must program Residentia...

Страница 10: ...ew The sole purpose of the self tapping screw is to tap the holes for the machine screws it may be discarded after use Keypad A keypad should be located near each exit entry door The keypad features a...

Страница 11: ...than those required such as the dining room bed rooms utility room furnace room and hallways Heat detectors rather than smoke detectors are recommended in kitchens at tics and garages due to condition...

Страница 12: ...Ademco 7720 Long Range Wireless System The RM3008 may be used to interface the GEM P3200M control panel to the Ademco 7720 transmitter in order to meet UL Central Station Grade A or Grade B requireme...

Страница 13: ...ansmitter to be tested by faulting the zone The transmitter signal strength can be displayed using the DISPLAY RF XMITTER STAT function Enter a Level 3 User Code or enter the Dealer Code press the A b...

Страница 14: ...T 1 2 The RED and BLACK flying leads must be connected to a 12VDC 4 6 or 7 AH Rechargeable Battery to serve as backup power in the event of AC Power Failure NOTE To calculate the available standby tim...

Страница 15: ...tance for seven keypads is 300 feet using 22 AWG wire NOTE When running keypad wire avoid wiring parallel to other types of wiring that can cause electrical interference WIRING CONNECTIONS REMOTE BUS...

Страница 16: ...selected see GEM P3200 Programming Instructions Connect the device controlled by the programmable output between terminal 15 and terminal 14 15 RESET OUTPUT EXPANDED ZONE CONFIGURATION The GEM P3200...

Страница 17: ...d to any programmed fire zones 9 32 Do not use in UL installations See page 9 Power must be obtained from terminal 28 and 29 If Fire Alarm Verification is de sired to reset the smoke detectors select...

Страница 18: ...ack or a CA31A jack for Canadian installations The Telco Line is used by the control panel to dial the central station and for downloading This line should not be connected to party lines or coin oper...

Страница 19: ...pad must be configured for a keypad tactile beep b entry sounder c keypad address d EZM address and e zone response To enter the GEM RP1CAe2 GEM K1CA Configuration Mode 1 Move jumper JP1 located at th...

Страница 20: ...ZMs it must be assigned a unique address or Group number see Keypad Programming Workbook similar to its keypad address If no other EZMs are to be used designate the keypad as Group 01 at the EZM ADDRE...

Страница 21: ...be selected as Keypad 1 Assign the keypad address number by selecting Jumpers J1 3 in accordance with the ta ble at left Note 1 Keypads are factory supplied with no jumpers in stalled and as such are...

Страница 22: ...ode only A Service Code is an Arm Disarm Code that is easily activated when needed and dormant at other times Intended for the occasional or temporary user repairman etc who would otherwise be denied...

Страница 23: ...EM RP1CAe2 GEM K1CA keypads only An S in the display e g EXIT TIME XXX S will appear as a re minder that the system is being armed with the Service Code active To turn off the Service Code disarm then...

Страница 24: ...an Auto Arm a User can press the R or A button until TO DE LAY AUTO ARM PRESS 1 4 N is displayed Enter the number of hours to delay arming followed by the U or D button If DELAY AUTO ARM Y N is displ...

Страница 25: ...number The zone will be unbypassed the next time the system is disarmed Security Bypass Zones programmed for Selective Bypass may be removed from the system prior to arming as follows 1 Enter a code...

Страница 26: ...le to the user s authority level will be suppressed and will not display 2 Press the PRIOR NO button to skip a function press the NEXT YES button to execute it 3 The GEM RP2ASe2 GEM K2AS displays abbr...

Страница 27: ...if programmed permits all zones designated as Day Zones to be turned on When selected a W will appear in the display GEM RP1CAe2 only as long as the Watch Mode is active To deactivate the Watch Mode...

Страница 28: ...K3DGTL Keypads Displays most recent openings and closings Line 1 displays event and date Line 2 displays time area and user To check previous events scroll back using the PRIOR button DISPLAY SYSTEM L...

Страница 29: ...status of transmitter NODATA transmission not yet received NORMAL transmitter s zone normal FAULT transmitter s zone open LOBATT transmitter battery low TAMPER transmitter case open S FAIL supervisory...

Страница 30: ...number E07 00 DOWNLOAD FAIL Download failure E08 00 TELCO LINE1 FAIL Telephone line failure system trou ble displays after a programmed delay E09 00 NOT PROGRAMMED System cold start E10 NNN KEYPAD AC...

Страница 31: ...n Access on Aux Output into the Aux 1 or Aux 2 option locations on the Wire less KeyFobs screen This feature also requires a valid time to be entered into the Aux Output Access Control in the Time Sel...

Страница 32: ...report to be sent to a cen tral station Thus should a user be forced to disarm he can silently signal an emergency while appearing to be merely disarming the system The Ambush Zone will automatically...

Страница 33: ...assed Note A zone in trouble that is not programmed for Auto Bypass will cause an alarm on arming after a 10 second arming delay If Auto Bypass Re entry is selected securing a zone that is programmed...

Страница 34: ...s The feature 2nd Call Answering Machine Override allows downloading after 1 the panel detects 1 or 2 rings 2 the panel does not detect another ring for 8 seconds 3 the panel detects another ring with...

Страница 35: ...Identification Number is 6789 the Closing Code is C The communicator will send the following report to the central station When alarm occurs 6789 35 Alarm Zone 5 Closing Report 1234 C1 Closing User 1...

Страница 36: ...niversal High Speed Ademco 685 Formats Ademco Slow Silent Knight Slow Silent Knight Fast Sescoa Vertex DCI Franklin Slow Franklin Fast Radionics Slow Radionics Fast Radionics BFSK Universal High Speed...

Страница 37: ...e report a Ring Back will be given Digital Dialer Test Activating the digital dialer test from the Function Menu ACTIVATE DIALER TEST will send the programmed report code to the central station Progra...

Страница 38: ...d properly Any program changes such as adding changing user codes adding users to an area or changing Entry Exit Delays will be processed properly with the panel armed Don t Clear Aux Relay with Arm D...

Страница 39: ...activated A minimum of 30 seconds is recommended Enable Set Time Date Message In the event of a memory corruption the loss of the system clock will occur and a message SET TIME DATE will be displayed...

Страница 40: ...e detector A short across the zone will cause a fire alarm which will be indicated at the keypad by a FIRE LCD display and pulsing sounder An open circuit on the Fire Zone will identify a trouble and...

Страница 41: ...l DIGITAL DIALER TEST Y N is displayed and then press NEXT YES to initiate the transmission of a Test Timer signal Note Test Timer reporting codes and Report Test Timer on Telco1 or Telco 3 must be pr...

Страница 42: ...e zone and 1234 is the Subscriber ID number If the Leading Digits are programmed as 98 1st digit Address Location 0520 y 9 2nd digit Address Location 0521 y 8 the Pager report will now appear as 983 0...

Страница 43: ...ystem RAM fail only the Master Security Code will work The Dealer Security Code is needed to enter the Dealer Program Mode thus allowing the dealer to program codes zone fea tures reporting features a...

Страница 44: ...econds Pre Dial Delay A Pre Dial Delay may be used whenever a delay is required before dialing It may be required when programming Dial Tone De tection which causes the communicator to wait before it...

Страница 45: ...signing or mapping events to relay numbers PCD Windows must be used to program Relay X 10 mapping Referring to the PCD Windows External Relay Control screen the Relay Entry column typically indicates...

Страница 46: ...is expected This feature supervises the sensor by verifying that the zone activates before the PIR timer runs out If no trip is de tected within the programmed Sensor Watch time a system trouble will...

Страница 47: ...t Telco 3 Start Exit Delay After Ringback When a closing report is successfully received the central station will acknowledge by returning a kissoff signal When the kis soff is received by the communi...

Страница 48: ...panel leaves the factory with no zones programmed for Auto Reset If Enable CP 01 Features is selected in the Easy Programming menu all non fire zones will not be programmed for Auto Reset System Troub...

Страница 49: ...3 is programmed for Double or Split Reporting Private telephone systems may require a Dial Tone Detection E or Pre Dial Delay D followed by an access number to obtain an outside line See Access Numbe...

Страница 50: ...elected the communicator will alternate between TouchTone and rotary dial to reach Telephone 1 then Telephone 2 See Backup Report on Telco 2 Trouble An abnormal zone condition a break in a normally cl...

Страница 51: ...ess Byte The Authority Level comprises an Option Code Refer to Programming Manual WI818 or WI1184 for descriptions of levels and options If reporting to a central station program User Closing and Open...

Страница 52: ...ntire Group If Enable Local Alarm on First ZoneAND Trip Address 2419 is programmed a trip on any Zone of the Group will cause an alarm output and alarm display at the keypad there will be no communica...

Страница 53: ...QTY EACH TOTAL GEM P3200 1 X 0 120 GEM EZM4 8 X 0 050 GEM EZM8 X 0 050 GEM RP1CAe2 GEM K1CA X 0 100 GEM RP1CAe2 GEM K1CA 1 X 0 035 GEM RP2ASe2 GEM K2AS X 0 065 GEM RP2ASe2 GEM K2AS 2 X 0 020 GEM RP3DG...

Страница 54: ...ecessary use this wiring legend to relocate wire leads to their proper terminals Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION col umn opt...

Страница 55: ...IEW 3 B ACTIVATE CHIME 1 ACTIVATE WATCH 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND C ACTIVATE LOCATE C EZM ZONE FIND C FUNCTION LEVEL A ACTIVATE DIALER TEST 3 DISPLAY ALARM...

Страница 56: ...TIVATE OVERVIEW 3 B ACTIVATE CHIME 1 ACTIVATE WATCH 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND C ACTIVATE LOCATE C EZM ZONE FIND C FUNCTION LEVEL A ACTIVATE DIALER TEST 3 DI...

Страница 57: ...TER ZONE XX E CHIME ZONES ENTER ZONE XX E CHIME 2 ZONES ENTER ZONE XX E EXIT ENTRY 2 ZNS ENTER ZONE XX E 50MS LOOP ZONES ENTER ZONE XX E AUX OUTPUT ZONES ENTER ZONE XX E SENSOR WATCH ZNS ENTER ZONE XX...

Страница 58: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 58 NOTES...

Страница 59: ...t about 15 seconds 01 OUT OF SYSTEM JP5 is located at the top right corner of the circuit board If a Compatibility Number other than 0000 is programmed OLD COMPAT XXXX is displayed KEYPAD PROGRAMMING...

Страница 60: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 60 GEM P3200 WIRING DIAGRAM...

Страница 61: ...d minimum default is 30 seconds If an attempt is made to change the Entry Delay time to less than 30 seconds the time will be entered as 30 seconds The maximum programmable time is 255 seconds The pan...

Страница 62: ...ted at address 0887 Keypad will display the following warning that the system is in Fault Find FAULT FIND RF SIG POWER If a 24 hour zone is tripped and not restored during Fault Find when the mode is...

Страница 63: ...All zones are programmed with report codes and as burg fire alarm types depending on whether they were selected as fire zones Zones not selected as fire are burg type 5 The reporting format is selecta...

Страница 64: ...connect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are co...

Страница 65: ...ssary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commiss...

Страница 66: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 66 Notes...

Страница 67: ...L NAPCO Security Systems X GEM P3200 Installation Instructions WI817F 10 05 Page 67 Notes...

Страница 68: ...ther assumes nor au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be...

Отзывы: