KEYPAD MESSAGES
The GEM-RP1CAe2/GEM-K1CA Keypad can display the following messages. The GEM-RP2ASe2 and GEM-K2AS keypads will dis-
play similar abbreviated messages that may scroll through two screens.
SYSTEM READY CW1
- All zones operating; system can be armed.
GEM-RP1CAe2 only: C = Chime Mode on; W = Watch Mode on;
1-8 = Area.
PLEASE WAIT
- Panel reporting to central station on arming. Wait for
ringback signal to exit.
EXIT TIME XXX SI1
- Exit delay in progress. XXX = exit time remaining
in 10-second decrements; GEM-RP1CAe2 only: S = Service Code
active; I = arming with Instant protection; 1-8 = Area.
ENTRY TIME XXX
- Entry delay in progress. XXX = entry time remain-
ing in 10-second decrements.
SYSTEM ARMED SI1
- Panel armed. GEM-RP1CAe2 only: S = Service
Code active; I = arming with Instant protection; 1-8 = Area.
CHECK STATUS CAW
- One or more zones not secured. Display
status for zone description(s). GEM-RP1CAe2 only: C = Chime
Mode on; W = Sensor Watch Mode on
CAN'T ARM/ZONES NOT NORMAL
- Arming attempted with Priority
Zone in trouble. Secure zone to arm.
DAY ZONE TRBL
- Trouble condition on Day Zone, followed by one or
more zone descriptions.
INVALID ENTRY/TRY AGAIN
- Wrong code/time/area number entered.
CAN'T ARM SYSTEM
- Arming attempted with System Trouble present.
Press the
C
button and then arm the system.
ALARM
- Alarm condition, followed by one or more zone descriptions.
****FIRE****
- Fire alarm condition, followed by one or more zone descrip-
tions.
FIRE TROUBLE
- Trouble condition on a Fire Zone. Press
C
button to silence the sounder. Correct the trouble, then press the
C
button again.
FIRE ALARM
- Alarm condition on a Fire Zone. Press the
C
but-
ton to silence the sounder. Correct the cause of the alarm, then
press the
C
button again.
ZONES BYPASSED
- (When Zones Bypassed displayed) Indicates
zones that have been deactivated.
OV(R-)
- Overview Mode (Status of up to 8 areas): R=Zone Ready; also,
Z=Zone Fault; A=Armed; B=Burglary Output; F=Fire Alarm; T=Fire
Trouble; C=Check Trouble; Display Mode.
SYSTEM TROUBLE
- A System Trouble display will be followed by one
or more of the following error codes:
E01-00 - AC POWER FAIL.
Power failure. Check power trans-
former. Check for blown fuse or circuit breaker; general
power outage.
E02-00 - LOW BATTERY.
Battery below 11 volts. If not recharged
within 24 hours, replace it.
E03-00 - COMM FAIL.
Unsuccessful communication to central
station.
Note:
Will also display if panel improperly pro-
grammed to report; i.e., Report Alarm, Report Codes, Sub-
scriber ID Numbers, etc. must be programmed.
E04-NN - WL TRBL.
Wireless transmitter supervisory failure. NN =
transmitter number.
E05-NN - WL LOBATT.
RF transmitter low battery. NN = transmit-
ter number.
E06-NN - RF REC TROUBLE.
RF receiver response trouble. NN
= receiver number.
E07-00 - DOWNLOAD FAIL.
Download failure.
E08-00 - TELCO LINE1 FAIL.
Telephone line failure (system trou-
ble displays after a programmed delay).
E09-00 - NOT PROGRAMMED.
System cold start.
E10-NNN - KEYPAD/ACM TROUBLE.
Keypad or ACM response
failure. NNN is keypad number (address).
E11-NNN - KEYPAD/ACM TAMPER.
Keypad or ACM cover
opened. NNN is keypad number (address).
E12-NN - BURG EZM TRBL.
Expansion zone module failure. NN
= module number.
E13-NN - BURG EZM TAMPER.
EZM module cover re moved.
NN = module number.
E14-NN - RELAY BOARD TRBL.
Relay board response failure.
NN = relay board number.
E15-NN - WL TAMPER.
Transmitter cover removed. NN = trans-
mitter number.
E16-NN - RF REC JAMMED.
Receiver jammed. NN = receiver
number.
E17-NN - RF REC TAMPER.
Receiver cover removed. NN = re-
ceiver number.
E18-NN - LOBATT KEYFOB.
Key fob transmitter low battery. NN
= key fob transmitter number.
E19-00 - USER MEM ERROR.
Internal memory error. Select RE-
SET SYSTEM TBL. Press the
J
button, then the
C
button.
E20-00 - DEALER MEM ERROR.
Same as above.
E22-NN - PIR SENSOR TRBL.
No trip detected on PIR Supervi-
sion Zone within programmed Sensor-Watch time. NN =
Zone number. To reset, press YES (
E
) button at
“
RESET SENSOR MSG
” function display.
E23-00 - BURG BUS FAILED.
Failure of 4-wire bus. Check Termi-
nals 11/12.
E24-00 - TIME FOR SERVICE.
A service message can be pro-
grammed through the PCD3000 Quickloader (event-schedule
screen) to remind the user to arrange for scheduled mainte-
nance. At the programmed date and time, the keypad
sounder will start to pulse and the display will read “
TIME FOR
SERVICE
” (GEM-RP1CAe2) or “
SERV
” (GEM-RP2ASe2). This
condition will behave as a system trouble and may be cleared
as such, i.e., press
C
to silence sounder; access RE-
SET SYSTEM TRBL, then press the
J
button.
E25-00 - TCP/IP COMMUNICATIONS.
Failure of communications
between the NL-MOD and the TCP/IP based (Intranet or
Internet) network.
E27-00 -
Printer Failure. Call installing company for service.
E39-00 - RF CAPACITY TRBL.
Receiver capacity error.
E40-00 - RF SELF TEST FAIL.
Receiver Self-Test error.
E51-00
- Alarm Output Supervisory.
E54-000 - LOW BATT / NO AC.
Power failure for ACM #1. Check
power transformer. Check for blown fuse or circuit breaker;
general power outage. Also may indicate battery below 11
volts. If battery not recharged within 24 hours, replace it.
E55-000 - LOW BATT / NO AC.
Power failure for ACM #2. Check
power transformer. Check for blown fuse or circuit breaker;
general power outage. Also may indicate battery below 11
volts. If battery not recharged within 24 hours, replace it.
E59-00 - TELEMETRY COMMUNICATIONS.
Failure of the inter-
face between the NL-MOD and the control panel.
E66-00 - SERVICE. "
Clean Me" warning--Smoke Detector dirty.
Clean detector or call installing company for service.
E99-00 -
Keypad panic shorted too long. GEM-RP2ASe2 / GEM-
RP3DGTL only.
NN OUT OF SYSTEM
- Keypad inoperative. NN = keypad number.
ALARM
- (After panel is disarmed) displays zones violated.
FAULT FIND
- Fault-find Mode activated.
LOCATE
- Locate Mode activated.
KEYP
A
D
MESS
AGES
Содержание Gemini GEM-P3200
Страница 58: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 58 NOTES...
Страница 60: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 60 GEM P3200 WIRING DIAGRAM...
Страница 66: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 66 Notes...
Страница 67: ...L NAPCO Security Systems X GEM P3200 Installation Instructions WI817F 10 05 Page 67 Notes...