Subscriber Identification Numbers
If reporting openings and/or closings, program Subscriber Opening/Closing Identification Numbers for each area for each tele-
phone number used. If reporting events, program Subscriber ID Numbers for each area for each telephone number used. Sub-
scriber ID numbers must be programmed for each area and telephone number, even if all are the same. Start with the left-most loca-
tion.
Sum Check
See Data Format
Supervised Bell Output
When the option Supervised Bell Output is enabled, a 2.2K ohm resistor must be installed across the bell or sounding device ter-
minals. In the event that the Burg Output is cut, or the circuit is opened, an E51-00 FIRE BELL TRBL trouble condition will occur.
Note: Due to the fact that there is a constant loop current flowing through the Burg Output circuit for supervision, some sirens or siren
drivers may emit a low volume hum or buzz if the 2.2K EOL resistor is not installed. If Supervised Bell Output is not required, this can
be eliminated by cutting resistor R207 which is located just to the right of the Burg Output relay adjacent to the Burg Output terminal.
Suppress “BYPASSED” Icon When Armed
Program to inhibit the LCD “
BYPASSED
” display while armed.
Swinger Shutdown
Swinger Shutdown is a common term used in the burglary alarm industry. It is a feature of an alarm panel that prevents multiple false
alarms from being generated from faulty detectors (or wiring) by limiting the number of alarms a zone may report during a single arm-
ing period. NAPCO has this programmable-by-zone feature named
Swinger Shutdown,
and has been available on its panels for
years. The SIA False Alarm Reduction standard CP-01 (to which the panel now complies) requires the SIA definition of "swinger
shutdown" on all non-fire zones. Our programmable feature allows three trips per arming period which is unacceptable in CP-01 in-
stallations. Therefore, to reduce confusion, the following defines both definitions of "Swinger Shutdown", namely (1) the
NAPCO Pro-
gramming Feature
and (2) the
CP-01 Requirement
:
Swinger Shutdown (NAPCO Programming Feature):
Program a zone with this feature to allow only three alarms per arming
period.
Auto-Reset
must also be programmed for the zone for this feature to work.
Swinger Shutdown (CP-01 Requirement
): To meet CP-01, all non-fire zones
must not
be programmed for Auto-Reset.
A zone
not programmed for Auto-Reset will trip only one alarm per arming period. The panel leaves the factory with no zones programmed
for Auto-Reset. If "Enable CP-01 Features" is selected in the Easy Programming menu, all non-fire zones will not be programmed
for Auto-Reset.
System Trouble Audible Automatic Timeout
Inhibit System Trouble Audible
In the event of a System Trouble while the system is disarmed, the keypad will scroll the trouble description in the display and
activate the sounder until [RESET] is pressed. If [RESET] has not been pressed within 10 minutes of the trouble, the sounder will
automatically turn off in 10 minutes.
To disable System Trouble Audible Automatic Timeout , enable
Disable System Trouble Audible Timeout
in the PCD-WINDOWS
Keypad Features screen. NOTE: If the system were Armed when the trouble occurred, the keypad would display the SYS TBL icon,
but NOT activate the sounder.
For installations where an audible on system trouble is not desired at all, the option,
Inhibit System Trouble Audible
can be en-
abled. Regardless of the system status, Armed or Disarmed, there will be no keypad sounder at all in the event of a system trouble.
However, the trouble will still scroll in the keypad display until [RESET] is pressed and the SYS TBL icon will display until the trouble
is restored. (Do Not program in UL Installations)
•
To disable System Trouble Audible, enable the option
disable System Trouble Audible
in the PCD-Windows Keypad Features
screen.
Tamper
EZM Tamper
Keypad Tamper
RF Tamper
Removing the cover of an expansion zone module will cause the sounder to pulse and the “
SYS/TRBL
” reminder to flash. The key-
pad will display “
E13-NN BURG EZM TAMPER
”, where “NN” denotes the module number. Press the
C
button to silence the sounder
(“
SYSTEM READY
” will display). Correct the problem, then select RESET SYSTEM TBL to manually reset the system trouble display.
Removing a keypad from the wall causes a similar system trouble indication. The keypad will display “
E11-NN BURG KPD TAMPER
”,
where “NN” denotes the keypad number. Press the
C
button to silence the sounder (“
SYSTEM READY
” will display). To manually
reset the system trouble, correct the problem then select RESET SYSTEM TBL.
Note:
If either of the tamper conditions is not corrected within 5 minutes, the system trouble will again display at the keypad.
A Tamper condition can be programmed to activate the burglary output and/or report using its associated system Report Code.
In wireless installations, when displaying RF transmitter status, a “Tamper” indication denotes that the transmitter case is open.
Telco Fail See Enable Telephone Line-Fault Test
TELCO FAIL ONLY WHEN ARMED
The Telco Line Cut Monitor will only be active when the system is armed.
Telco Line Test Delay
See Enable Telephone Line-Fault Test; Time Selection
GLOSS
A
RY
Содержание Gemini GEM-P3200
Страница 58: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 58 NOTES...
Страница 60: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 60 GEM P3200 WIRING DIAGRAM...
Страница 66: ...X GEM P3200 Installation Instructions L NAPCO Security Systems WI817F 10 05 Page 66 Notes...
Страница 67: ...L NAPCO Security Systems X GEM P3200 Installation Instructions WI817F 10 05 Page 67 Notes...