71
S 07
MAINTENANCE
Overview of the raw water pump
1
Gasket
5
Raw water pump
2
Spacer
6
Fittings
3
Screw
7
Washers
4
Gasket
1
Raw water pump (1 to 16)
9
Pin
2
10
Plate
3
Pump shaft
11
Cover screw
4
Guide
12
Cam screw
5
Pump impeller
13
Spi gasket
6
Cover
14
O-ring
7
Gasket
15
Ball bearing
8
Cam
16
Stop ring
Raw water pump installation
1.
Check the condition of the spacer contact surface be
-
fore mounting the seal and the pump.
2. Replace the gasket (2) and after greasing it on both
sides, install the raw water pump (3) using 4 screws
(1) with their washers.
3. Install the hose to the heat exchanger using the hose
clamps. Tighten the clamp to the correct torque.
Specifications
Clamps - Tighten
-
ing torque
5 N·m
(3.69 ft-lbs)