70
S 07
MAINTENANCE
WARNING!
Do not start the engine without coolant. Use a mixture
of 50% clean, fresh, non-calcareous water and 50% anti-
freeze to top up the cooler. For the water-antifreeze mix-
ture, the antifreeze ratio should be 50%. Tighten the heat
exchanger cap. If the cap is loose or not properly tight-
ened, water may leak out and the motor may overheat. Do
not use antifreeze and scale inhibitor at the same time.
Never mix different types or brands of coolants or anti-
freeze.
•
See coolant replacement section.
RAW WATER PUMP REPLACEMENT
DANGER!
Never work on the seawater circuit without taking care to
isolate the suction and discharge valves.
Removal of the raw pump
1. Dismantle the raw water outlet hose (see chapter Re-
placement of hoses and clamps)
2. Unscrew and remove the 4 screws (1) then remove
the pump (2) with its seal (3).
3.
Clean the surface of the spacer.