8.4 Connection of the robot
8.4 Connection of the robot
WARNING
There is possibility of electric shock, so when performing the wiring work make sure to turn
OFF the power of the robot’s controller and remove the connector of the primary power side.
IMPORTANT
Make sure to match the robot number (#1 to #4) and CFDL connector number (#1 to #4).
In case of not matching the number then, robot cannot be operated.
Connect the CFDL controller and the each robot refers to the figure b elow. For connection cables, please use
any of those below. 2 cables are contained in 1 set. 1 set is necessary per one robot.
Item No.
Length
E000E-J1-02-B
2m
E000E-J1-05-B
5m
E000E-J1-10-B
10m
E000E-J1-15-B
15m
E000E-J1-20-B
20m
8.4.1
(A) “CFDL1-0000” + One Robot
1
CNR03
CNPW
CNR01
CN1
8.4.2
(B) “CFDL2-0000” + Two Robots
2
1
CNR03
CNPW
CNR01
CN1
CNR03
CNPW
CNR01
CN1
CN1(#1)
CNPW(#1)
ROBOT #1
CN1(#1)
CNPW(#1)
ROBOT #1
CN1(#2)
CNPW(#2)
ROBOT #2