Troubleshooting
Manual No. 3000863
4-5
unique SCSI ID.
• The SCSI bus may be improperly terminated. Verify that the bus is
terminated properly.
BIOS INITIALIZATION SUCCESSFUL
SCSI 0, XXXXX
SCSI 1, XXXXX
If the system hangs with this message on the display, there may be a SCSI
bus termination problem.
• Verify that the SCSI bus is terminated properly.
ENTERING CARD DIAGS/INIT CARD=OO
DIAGS ERROR IN DIAGNOSTIC TESTING.
DIAGS:S/G RAM FAILURE LOW->ADDRESS=XXXX
ACTUAL=XXXX EXPECTED=XXXX
S/G RAM FAILURE HI->ADDRESS=XXXX
ACTUAL=XXXX EXPECTED=XXXX
This message indicates a RAM diagnostic failure. Problems may include the
following:
• The adapter card is bad. Stop and restart the system to retry the
operation.
• The adapter card is not compatible with the system. Check to see if
your system uses the VIA Chipset. If it does, revision CF or earlier is
not compatible with the adapter. CG or later is compatible with the
adapter.
• The BIOS is not PCI compliant.
ERROR: NON-PCI COMPLIANT SYSTEM BIOS, PLEASE UPGRADE.
This is not an adapter-related problem. Call the motherboard manufacturer
for information on upgrading your system BIOS.