18. TROUBLEShOOTING ChECKLIST FOR ThE INSTALLER
IMPORTANT:
The following check list is provided for the benefit of the qualified installer.
WARNING: SWITCh OFF ThE ELECTRICITy AT ThE ISOLATOR BEFORE
REMOVING ThE FRONT COVER TO MAKE ChECKS.
Q. Shower switches off too quickly.
A. Shower timed operation has been
set too low. See changing the shower
programmes on page 16.
Q. Poor temperature control.
A.
Check the inlet and outlet thermisters
to see if they are in circuit.
Check for blockage in the inlet filter (see
page 25).
Q. Water too cold.
A.
Check the circuit through the thermal
cut out.
Check circuit through all 3 elements.
NOTE:
Test to be done using a low
voltage resistance meter whilst the power
is switched OFF at the isolating switch.
Check working voltage.
Q. Poor or no control over water flow.
A.
Replace the water flow valve head
works.
Q. No water when start / stop button is
pressed.
A.
Check the water supply isolating valves
are fully open.
Check circuit through the solenoid coil.
Q. Pressure relief valve operated.
A.
Check for cause of high pressure
such as blocked shower hose or shower
handset. Replace pressure relief valve
disc. (Note: this is not covered under the
product guarantee.)
Q. Temperature output is limited.
A.
To maintain BEAB Care performance
for additional user safety, Thermostatic
Care units have the maximum outlet
temperature factory set and limited to a
nominal 41 °C.
The Thermostatic Plus models are
supplied with the maximum outlet
temperature limited to a nominal 47 °C.
Maximum outlet temperature options can
be selected via dip switches mounted
on the display PCB. This should be
completed as described on page 16.