25
16. ROUTINE MAINTENANCE
ShOWER hANDSET AND INLET WATER FILTER CLEANING INSTRUCTIONS
The shower handset should be cleaned periodically to remove lime scale or debris
which will reduce the performance of the shower. The frequency of the cleaning will
vary according to local water quality.
PERIODICAL MAINTENANCE
1.
To break away scale deposits on a daily basis
simply rub your thumb over the surface whilst
the shower is running.
2.
If scale deposits are stubborn, soak the
showerhead in a proprietary limescale
remover and rinse thoroughly before use.
3.
Remove the filter from the bottom of the
shower clean out any debris by washing in
clean water. Refit filter.
electronic control capability of the
shower it is most unlikely that this
device will operate.
11.
A pressure relief device is fitted
to safeguard against a build up of
pressure in the heater. It provides
protection to the heater should
an excessive build up of pressure
occur. If this device operates then a
replacement part will be required.
12.
If the shower has shut down as
described in 10b above the shower
unit will remain locked out until the
water outlet temperature of the shower
falls to 37 °C. This could take some
time as water will not be flowing.
Alternatively follow the procedure detailed
below:
• Ensure that the water supply is back to
normal.
• Stand clear of the shower.
• Press the warmer (+) and cooler (-)
buttons together for more than 3
seconds.
• The water solenoid will energise and
allow cold water to flow into the shower
and purge the hot water out of the heat
exchanger.
• Press the start/stop button to switch
the unit off.
• Press the start/stop button and the unit
will re-start and normal showering can
be commenced.
HOW YOUR SHOWER WORKS (CONT.)
1
2
3