background image

22

14. OPERATING ThE ShOWER 

1.  

Switch on the electrical supply at the 

pull cord or wall mounted switch. The 

power on

 neon will illuminate indicating 

the switch is on.

2.  

Please do not stand under the spray 

from shower handset as initially the 

water will be cold. Press the shower 

start /stop button for immediate water 

flow. This is confirmed with a single 

audible bleep.

3.  

The “Secret Until Illuminated” seven 

segment display will activate and show 

through the front cover – displaying 

the FIXED pre-programmed start up 

temperature of digit 8 for Thermostatic 

Care models or the MEMORY start 

up temperature for the Thermostatic 

Plus. The unit will indicate the start 

up temperature has been reached by 

sounding a DOUBLE bleep

.

4.  

The shower outlet temperature will 

increase until it reaches this pre- 

determined temperature. This could 

take up to 30 seconds if the shower is 

starting from cold.

5.

  The flow control will indicate the water 

flow through the shower:

3x LEDs illuminated:  MAXIMUM flow 

2x LEDs illuminated:  ECO flow 

1x LED illuminated:    MINIMUM flow

6.  

The maximum temperature lock LED  

will be illuminated when Maximum 

Temperature PROGRAMME 1 or 2  

is set. PROGRAMME 1 is the factory 

default setting on Care models where 

the maximum outlet temperature is 

limited to a nominal 41 °C. This feature 

is included for additional safety for use 

in the care sector, less able or by the 

extended family.  

 

The LED will also be illuminated if 

PROGRAMME 2 has been selected on 

installation which limits the maximum 

outlet temperature to a nominal 43 °C.

NOTE: 

The “Secret Until Illuminated” 

seven segment display indicates the 

shower outlet temperature where 0 is 

cold, digit 1 represents a nominal 30 °C 

and digit 9 represents the maximum 

temperature:
PROGRAMME 1:  a nominal 41 °C  

(the default setting for Care models)
PROGRAMME 2: a nominal 43 °C 
PROGRAMME 3: a nominal 47 °C  

(the default setting for Plus models)

7.

  The shower outlet water temperature 

will be controlled thermostatically during 

the shower. If you wish to change this 

temperature then make adjustments 

described below.

TO INCREASE ThE TEMPERATURE

1.  

Press the warmer (+) button 

ONCE

The digit will move, for example from 

6 to 7 confirmed by a single audible 

bleep. The water temperature will 

increase by a nominal 1.5–2 °C. Wait a 

few seconds for the shower to increase 

the temperature to the new setting.

2.  

Repeat this if necessary to achieve 

your ideal temperature setting waiting 

each time for the new temperature to 

be achieved.

NOTE: 

If digit 9 is displayed by the seven 

segment temperature display then it will 

NOT be possible to request a higher outlet 

temperature as this is limited by the PCB 

control for additional safety.

Содержание Thermostatic Care QI

Страница 1: ...ntrol Instantaneous Electric Shower Installation and User Instructions IMPORTANT This Step by Step guide should be given to the customer after installation and demonstration Thermostatic Care QI Therm...

Страница 2: ...s shower models have been specially designed for Quick Installation Both water and electrics can enter the shower unit from 8 different positions The unit is wired internally to accept mains cable fro...

Страница 3: ...ntee Card Thermostatic Care QI Temperature Flow Control START STOP Temperature FLOW Shower accessories shown may vary with product type 1 ShowerUnit 2 ShowerHandset 6 Flexible ShowerHose 9 Additional...

Страница 4: ...e user operating instructions Tick off as you complete 1 SHOWER UNIT FAMILIARISATION Thermostatic Care QI Temperature Flow Control START STOP Temperature FLOW Temperature buttons Warmer push button Co...

Страница 5: ...entered inside the unit because of an incorrectly fitted cover DO NOT place items such as soap shampoo or other such bottles on top of the unit as liquid could leak through the joint between the cover...

Страница 6: ...the wall plugs Chose a flat piece of wall to avoid the possibility of distorting the back plate and making the front cover a poor fit Exercise great care when using power tools near water The use of a...

Страница 7: ...solating valve must be fitted between the rising main and the unit to comply with water regulations and to allow for routine maintenance and servicing BATH COLD WATER MAINS SUPPLY SEPARATE PERMANENTLY...

Страница 8: ...8 litres per minute The maximum static pressure is 1000kPa 150lb sq in 10 Bar NOTE For 9 5kW units the minimum running pressure must be obtained at 9 L min For 10 5kW units the minimum running pressur...

Страница 9: ...the handset Remove the four front cover fixing screws and lift the cover off complete with the warmer and cooler push buttons and flow control knob in place Note there is a connector and lead attache...

Страница 10: ...GUIDE Showerunitcanbemounted eithersideofriserrail Heightof showerhead andshower tosuituser s requirements Mainscoldwatersupply eithertop bottom left rightorrearentry 25mmminimum Outlineofbathor showe...

Страница 11: ...diagram right the shower unit can be both plumbed and wired from 8 different positions n Top right n Top left n Bottom right n Bottom left n Right side n Left side n Rear right n Rear left Removable...

Страница 12: ...nections CONT The shower back plate incorporates into the lower right and left hand side of the back plate removable trim sections to allow easy access when deciding on and connecting to the water mai...

Страница 13: ...50 Hz a c electrical supply ELECTRICAL SPECIFICATIONS IMPORTANT The heating elements on the UK models are manufactured to 240V specification and will give a lower kW rating if the voltage supply is b...

Страница 14: ...L The outer sheath of the supply cable must be striped back to the minimum length as illustrated and the earth conductor must have an earthing sleeve fitted IMPORTANT Ensure that the terminal block s...

Страница 15: ...block IMPORTANT DO NOT switch on the electricity supply until the shower cover has been fitted The diagram below shows a schematic wiring diagram IMPORTANT The use of connections within the unit or o...

Страница 16: ...atic Care models are factory set in BEAB Care mode with settings as follows the audible feedback is ON single bleep on each push button command maximum temperature lock set to PROGRAMME 1 This limits...

Страница 17: ...ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP ON DIP ON DIP ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP...

Страница 18: ...lay PCB connector to the rear of the front cover as illustrated making sure that the connector pins are fully engaged The cover can now be fitted and secured with the four fixing screws provided Follo...

Страница 19: ...ing the locking cap Then fit the soap dish dampening the rail will make it easier to slide on Finally fit the hose retaining ring onto the bottom of the rail below the soap dish 6 Replace the rail ass...

Страница 20: ...er to fill the unit this only happens on the first start up operation IMPORTANT If the button does not respond ensure that the flying lead from the PCB has been connected to the back of the front cove...

Страница 21: ...UT DOWN operation PHASED SHUT DOWN The Phased Shut Down operation is activated when the shower is stopped using the start stop button It switches the heating elements OFF but allows the water to run f...

Страница 22: ...outlet temperature is limited to a nominal 41 C This feature is included for additional safety for use in the care sector less able or by the extended family The LED will also be illuminated if PROGRA...

Страница 23: ...rol valve will automatically reduce the flow to allow the unit to reach and maintain the outlet temperature selected Alternatively the medium or low flow can be chosen for comfort and economy Switch t...

Страница 24: ...ned on and off by the solenoid valve built into the shower activated by the start stop push button on the front cover 9 The water flow inlet and outlet water temperatures are measured and monitored to...

Страница 25: ...A pressure relief device is fitted to safeguard against a build up of pressure in the heater It provides protection to the heater should an excessive build up of pressure occur If this device operate...

Страница 26: ...t water will initially be emitted On the shower unit press and hold the warmer and cooler buttons for a minimum of 3 seconds until COLD water flows into the shower and through to the shower handset Wh...

Страница 27: ...zontal bars in the display counting down 3 2 1 OFF This feature ensures a cool start up temperature for the next user Q Water is dripping from the bottom of the shower A Safety pressure relief may hav...

Страница 28: ...r no control over water flow A Replace the water flow valve head works Q No water when start stop button is pressed A Check the water supply isolating valves are fully open Check circuit through the s...

Страница 29: ...to charge the claimant for parts and labour at current rates This guarantee is given in addition to and does not affect your statutory rights Exclusions 1 Any product found to be defective during this...

Страница 30: ...s not apply to normal wear and tear accidental damage inappropriate use including inappropriate cleaning or other events outside the manufacturer s control 7 This guarantee applies only to the product...

Страница 31: ...product development we reserve the right to alter the specification as necessary In the unlikely event that you need to make a claim on our guarantee please contact MX Customer Care on 0845 505 2211 o...

Страница 32: ...CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials o...

Отзывы: