background image

2

CONTENTS 

QI FEATURES

QI Features 

2

Pack Contents 

3

Installation

  1. Shower Unit Familiarisation 

4

  2. Installation Check List 

4

  3. Important Safety Information 

5

  4. General Installation Layout Guide  7
  5. Important Installation Information   8
  6. Fixing the Shower to the Wall 

9

  7. Product Positioning Guide 

10

  8. Plumbing Connections 

11

  9. Electrical Connections 

13

10.  Changing the Operational  

 

Programmes 16

11. Fitting the Front Cover 

18

12. Riser Rail Fitting Instructions 

19

13. Commissioning the Shower 

20

User Guide

14. Operating the Shower 

22

15. How Your Shower Works 

24

16. Routine Maintenance 

25

17. Troubleshooting and FAQs 

26

18.  Troubleshooting Checklist for  

the Installer 

28

19. Product Warranty 

29

20. Service Policy 

31

QI

QUICK INSTALLATION

a guide for installers

The MX range of QI Thermostatic 

Care and Plus shower models have 

been specially designed for Quick 

Installation. Both water and electrics 

can enter the shower unit from 8 

different positions. The unit is wired 

internally to accept mains cable from 

both the left and right hand sides of 

the back plate. 
Removable corner sections allow 

for easy plumbing connections. 

The screw mounting hole positions 

are visible when the front cover is 

removed. The top two fixing holes are 

vertical key hole slots and the bottom 

fixing hole is a horizontal slot to allow 

for alignment. The inlet water filter is 

positioned so that it can be removed 

quickly without taking the front cover 

off for routine maintenance.
The MX QI Thermostatic Care and 

Plus electric showers are designed 

for domestic, light commercial 

and healthcare applications and 

are approved to the BEAB Care 

performance standard.

These instructions contain all the 

necessary fitting and operating 

instructions for your electric shower. 

Care taken during the installation 

will provide a long, trouble free life 

from your shower.

Содержание Thermostatic Care QI

Страница 1: ...ntrol Instantaneous Electric Shower Installation and User Instructions IMPORTANT This Step by Step guide should be given to the customer after installation and demonstration Thermostatic Care QI Therm...

Страница 2: ...s shower models have been specially designed for Quick Installation Both water and electrics can enter the shower unit from 8 different positions The unit is wired internally to accept mains cable fro...

Страница 3: ...ntee Card Thermostatic Care QI Temperature Flow Control START STOP Temperature FLOW Shower accessories shown may vary with product type 1 ShowerUnit 2 ShowerHandset 6 Flexible ShowerHose 9 Additional...

Страница 4: ...e user operating instructions Tick off as you complete 1 SHOWER UNIT FAMILIARISATION Thermostatic Care QI Temperature Flow Control START STOP Temperature FLOW Temperature buttons Warmer push button Co...

Страница 5: ...entered inside the unit because of an incorrectly fitted cover DO NOT place items such as soap shampoo or other such bottles on top of the unit as liquid could leak through the joint between the cover...

Страница 6: ...the wall plugs Chose a flat piece of wall to avoid the possibility of distorting the back plate and making the front cover a poor fit Exercise great care when using power tools near water The use of a...

Страница 7: ...solating valve must be fitted between the rising main and the unit to comply with water regulations and to allow for routine maintenance and servicing BATH COLD WATER MAINS SUPPLY SEPARATE PERMANENTLY...

Страница 8: ...8 litres per minute The maximum static pressure is 1000kPa 150lb sq in 10 Bar NOTE For 9 5kW units the minimum running pressure must be obtained at 9 L min For 10 5kW units the minimum running pressur...

Страница 9: ...the handset Remove the four front cover fixing screws and lift the cover off complete with the warmer and cooler push buttons and flow control knob in place Note there is a connector and lead attache...

Страница 10: ...GUIDE Showerunitcanbemounted eithersideofriserrail Heightof showerhead andshower tosuituser s requirements Mainscoldwatersupply eithertop bottom left rightorrearentry 25mmminimum Outlineofbathor showe...

Страница 11: ...diagram right the shower unit can be both plumbed and wired from 8 different positions n Top right n Top left n Bottom right n Bottom left n Right side n Left side n Rear right n Rear left Removable...

Страница 12: ...nections CONT The shower back plate incorporates into the lower right and left hand side of the back plate removable trim sections to allow easy access when deciding on and connecting to the water mai...

Страница 13: ...50 Hz a c electrical supply ELECTRICAL SPECIFICATIONS IMPORTANT The heating elements on the UK models are manufactured to 240V specification and will give a lower kW rating if the voltage supply is b...

Страница 14: ...L The outer sheath of the supply cable must be striped back to the minimum length as illustrated and the earth conductor must have an earthing sleeve fitted IMPORTANT Ensure that the terminal block s...

Страница 15: ...block IMPORTANT DO NOT switch on the electricity supply until the shower cover has been fitted The diagram below shows a schematic wiring diagram IMPORTANT The use of connections within the unit or o...

Страница 16: ...atic Care models are factory set in BEAB Care mode with settings as follows the audible feedback is ON single bleep on each push button command maximum temperature lock set to PROGRAMME 1 This limits...

Страница 17: ...ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP ON DIP ON DIP ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP...

Страница 18: ...lay PCB connector to the rear of the front cover as illustrated making sure that the connector pins are fully engaged The cover can now be fitted and secured with the four fixing screws provided Follo...

Страница 19: ...ing the locking cap Then fit the soap dish dampening the rail will make it easier to slide on Finally fit the hose retaining ring onto the bottom of the rail below the soap dish 6 Replace the rail ass...

Страница 20: ...er to fill the unit this only happens on the first start up operation IMPORTANT If the button does not respond ensure that the flying lead from the PCB has been connected to the back of the front cove...

Страница 21: ...UT DOWN operation PHASED SHUT DOWN The Phased Shut Down operation is activated when the shower is stopped using the start stop button It switches the heating elements OFF but allows the water to run f...

Страница 22: ...outlet temperature is limited to a nominal 41 C This feature is included for additional safety for use in the care sector less able or by the extended family The LED will also be illuminated if PROGRA...

Страница 23: ...rol valve will automatically reduce the flow to allow the unit to reach and maintain the outlet temperature selected Alternatively the medium or low flow can be chosen for comfort and economy Switch t...

Страница 24: ...ned on and off by the solenoid valve built into the shower activated by the start stop push button on the front cover 9 The water flow inlet and outlet water temperatures are measured and monitored to...

Страница 25: ...A pressure relief device is fitted to safeguard against a build up of pressure in the heater It provides protection to the heater should an excessive build up of pressure occur If this device operate...

Страница 26: ...t water will initially be emitted On the shower unit press and hold the warmer and cooler buttons for a minimum of 3 seconds until COLD water flows into the shower and through to the shower handset Wh...

Страница 27: ...zontal bars in the display counting down 3 2 1 OFF This feature ensures a cool start up temperature for the next user Q Water is dripping from the bottom of the shower A Safety pressure relief may hav...

Страница 28: ...r no control over water flow A Replace the water flow valve head works Q No water when start stop button is pressed A Check the water supply isolating valves are fully open Check circuit through the s...

Страница 29: ...to charge the claimant for parts and labour at current rates This guarantee is given in addition to and does not affect your statutory rights Exclusions 1 Any product found to be defective during this...

Страница 30: ...s not apply to normal wear and tear accidental damage inappropriate use including inappropriate cleaning or other events outside the manufacturer s control 7 This guarantee applies only to the product...

Страница 31: ...product development we reserve the right to alter the specification as necessary In the unlikely event that you need to make a claim on our guarantee please contact MX Customer Care on 0845 505 2211 o...

Страница 32: ...CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials o...

Отзывы: