VJ-1604
Maintenance Manual
9 Troubleshooting
9-15
Rev.-00
NOTE
• The square bracket pair in a message may contain the applicable command code.
• For the PC settings, refer to your PC's operation manual.
9.2.5
Errors Requiring Reboot
This section describes the contents of reboot-requiring errors as well as the check items and recovery actions.
These errors are issued when any of the following critical problems occurs.
•
Obstacle that prevents the machine's operation
•
Damage of electric circuits (boards, motors, sensors)
•
Abnormal operation of control programs
When any of the above conditions occurs, the machine follows the steps shown below before stopping its
operation.
1. Turn OFF the driving system power automatically.
2. Flash all lamps in the operation panel and generate intermittent audible alarm.
3. Display the applicable error message on the LCD.
The error can be cancelled by removing the error causes and restarting the machine.
(1) CPU system serious error
Table 9-6 Symptoms and Check Items for CPU System Serious Errors
No.
Message
Event/
symptom
Check item
Action
Reference
1
E 001 error
DRAM
Standard
DRAM error:
Abnormal
condition in
standard
memory
mounted on
MAIN board
assembly
Main board assembly
may be defective.
Replace MAIN board
assembly.
"4.4.7
Replacing
MAIN
Board" p.4-
49
Содержание ValueJet VJ-1604
Страница 2: ......
Страница 14: ...VJ 1604 Maintenance Manual 12 ...
Страница 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Страница 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Страница 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Страница 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Страница 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Страница 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Страница 421: ......
Страница 422: ......