VJ-1604
Maintenance Manual
9 Troubleshooting
9-43
Rev.-00
12
Ink cartridge cannot
be detected even if
installed.
1. Are the following
self-diagnosis
functions detected as
normal when
checked with
specified cartridge
securely inserted?
•
Detection of
presence of ink from
"Ctrl 2: Sensor" ->
"Sen.3: etc" -> "12:
Ink END"
•
Detection of
presence of cartridge
from "Ctrl 2: Sensor"
-> "Sen.3: etc" ->
"11: Ink NOT
KCMY"
•
Follow the steps for the
message "[KCMY] No
Cartridge".
•
After adjustment/
replacement, execute
initial ink charge from
"Update 1: Head Rank"
of self-diagnosis
function.
"(1) Head
Rank" p.5-50
2. Is specified cartridge
status detected as
normal when
checked through
"Ctrl 2: Sensor" ->
"Sen.3: etc" -> "7-10:
[KCMY]Ink ID" of
self-diagnosis
function with
specified cartridge
securely inserted?
•
Follow the steps for the
message "Insert
specified cartridge".
•
After adjustment/
replacement, execute
initial ink charge from
"Update 1: Head Rank"
of self-diagnosis
function.
"(1) Head
Rank" p.5-50
Table 9-9 Symptoms, Check Items and Actions for Initial Operation Problems (Continued)
No.
Symptom
Check item
Action
Reference
Содержание ValueJet VJ-1604
Страница 2: ......
Страница 14: ...VJ 1604 Maintenance Manual 12 ...
Страница 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Страница 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Страница 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Страница 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Страница 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Страница 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Страница 421: ......
Страница 422: ......