6. Detach the PF speed reduction belt.
NOTE
When installing the PF motor assembly, ensure that the PF speed reduction belt is evenly guided
along the center part of the PF motor assembly pulley by moving the speed reduction pulley by hand.
7. Replace the PF speed reduction belt.
8. Retain the PF motor by pushing the motor backward.
9. Confirm that the PF speed reduction belt is not loosened.
10. To reassemble the unit, reverse the removal procedure.
4.6.2
Replacing PF Motor Assembly
CAUTION
Do not touch the motor right after starting-up the plotter. Otherwise, you may be burned.
1. Initialize the PF motor counter.
"5.11.1 Parameter Initialization Menu" p.5-47
2. Open the maintenance cover L.
3. Remove the side maintenance cover L.
"4.2.5 Removing Side Maintenance Cover L" p.4-12
4. Remove the rear side cover.
"4.2.8 Removing Rear Side Cover" p.4-15
5. Detach the PF speed reduction belt.
"4.6.1 Replacing PF Speed Reduction Belt" p.4-60