2966
7.1.2.5. Checking the tightness of the working platform bolts
Figure. 7.1.2.5. - 116. Working platform bolts
1. Check that the 6 bolts (M12) (2) of the working platform are tight.
Tighten the bolts, if needed.
2. Check that the 4 bolts (M16) (1) near the lifting cylinder are tight.
Tighten the bolts, if needed.
Figure. 7.1.2.5. - 117. Working platform U-bolts
3. Check that the 8 nuts ( M8)(2) of the U-bolts (1) are tight.
Tighten the bolts, if needed.