MAINTENANCE (PUMP)
Figure 17. Pump Vacuum Tester
PLACE VACUUM
TESTER OVER
PUMP SUCTION
PORT
CAUTION
DO NOT RUN PUMP
WITHOUT WATER.
DISCHARGE
PORT
PUMP VACUUM
TESTER
ACCEPTABLE READING
SHOULD BE BETWEEN
-25 AND -20 IN. HG.
25 IN. HG. TRANSLATES
INTO 25 FEET OF LIFT
AT SEA LEVEL.
DIRECTION
OF WATER
FLOW