PAGE 18 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
CONTROL PANEL
Table 6. Pilot Lamps Indicators
Light/Flash Pattern
Operation Status
Red and Green Lamps State
Green and Red Lamps
OFF
No battery power
(Starter Switch — OFF).
Green and Red Lamps
ON
Battery power supply is
On and Standby Mode
(Starter Switch — ON).
Green Lamp ON
Red Lamp OFF
Engine running
Pump priming
Manual Mode.
Green Lamp FLASHING
(in 1 sec intervals)
Red Lamp OFF
Auto/Standby Mode.
Red Lamp FLASHING
(in 1 sec intervals)
Green Lamp OFF
Priming Failure
(No water for priming).
Green and Red Lamps
FLASHING in 0.5 sec
intervals
Wrong float connection
(suh as upsidedown
connection of top/bottom).
Red Lamp FLASHING
2 times, OFF for 3 sec
then repeats
Green Lamp OFF
Abnormal Engine RPM
(low fuel or starting
failure).
Red Lamp FLASHING
3 times, OFF for 3 sec
then repeats
Green Lamp OFF
Failure of electrical
connections from engine
to control box.
Red Lamp FLASHING
5 times, OFF for 3 sec
then repeats
Green Lamp OFF
Circuit or ECU error in
control box.