Mod. 6609d-6612d:
Automatic Forms Cutter
13.12.2006
-52-
4.4 Technical change of the main PCB·s
The actual delivered
Automatic Forms Cutter
(dated week 43/2000) are with a potentiometer (to adjust the
optical power) on the main PCB.
The reason for this change is the ageing of the light emmiting
diodes (LED·s) used in the LED block. The optical power of the
LED·s decreases faster, ages faster, as specified b y the
manufacturer! As consequence, after several years of using, the
head unit (Mod. 6600 Automatic Forms Cutter , Mod. 6618
Pinless-Cutter , Mod. 6683 Cut-Sheet-Feeder or Mod. 6790
Cutsheet Guillotine shows the error message 31, 32, 33, or 34.
That means the DA-values are not within the allowed range.
(Further reasons for this error message are: dirt o n encoder disc,
distance between scanner head and encoder disc is not correct or
encoder disc is scratched.) This also has not change after this
modification. Please really note the technical service manual.
In addition to the above mentioned potentiometer, which is
mounted from now on, we changed software details, which are not
visible from outside. The control range was extende d, so in future
times the space of time the error message 31-34 appears is
widened (caused by deviating DA-values!). In addition the DA-
values are now directly shown on the display after running "service
routine 10" (during turn of the Poti). Please note that the displayed
values (for every channel one value) can always be different. By
manufacturing tolerances of the semiconductors and of the fibre
cable, always individual differences result within the 4 channels!
Independant of this, the DA-values should be between 70 and 130
- Total control range up to 250 (Important: Adjust the machine at
room temperature)! This range was settled new!
If the adjusted values are lower than 70 the Poti must be turned to
the left (lower optical power!). More than 130 - tu rn the Poti to the
right (more optical power!). After poti adjustments service "routine
10" must always be restarted in order to adjust the new actuall
DA-values automatically.
If the deviation between the 4 channels (no more in the range 70-
130 = approx. 40 DA-points difference) is to high, it is
recommended to change the deviating channel. The fibre cable or
the light emitting diode or the detector diode.
With the technical modifications described above, i t is possible for
the service technician on site to carry out themselves the
corresponding adjustments and as result extend the period
essentially, until the light emitting diodes must be changed.
Содержание 6609
Страница 1: ...Braillo Cut Operating Instructions Automatic Forms Cutter Model 6609d 6612d Release 12 12 2006 ...
Страница 4: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 4 ...
Страница 35: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 35 OMR data list ...
Страница 40: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 40 OMR data list ...
Страница 53: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 53 4 4 1 Connections and electrical settings ...