Mod. 6609d-6612d:
Automatic Forms Cutter
13.12.2006
-34-
Example 2:
The same 6 functions as in example 1 are to be carried out:
deflector unit 1,2,3,
collector, enveloping
and
stop.
In order to limit the number of lines to be read, i t is also possible to allocate one function
to several marks.
E.g. If there is a mark in lines 2 and 3 at the same time, the form should be sent to
deflector unit 3 (see illustration p. 38)
Whe
r
e several marks are to be used, the 5-digit code number is worked out by adding them together. Thus the
number for deflector unit 2 + deflector unit 1 + AL = 2 + 4 + 1 = 7.
The 5-digit code number for enveloping and AL is thus 00017. Let us now consider the whole block of marks as a
complete unit. The adjustment line contains the first mark, since it is the first to pass the reading head. Deflector
unit 2 is thus the second mark, and so on. We can use Table 1 to find the appropriate 5-digit code number for any
combination of marks. In our example these are:
1.
AL
+
collector
=
00009
2.
AL
+
enveloping
=
00017
3.
AL
+
deflector unit 1
=
00005
4.
AL
+
deflector unit 2
=
00003
5.
AL
+
deflector unit 3
=
00007
6.
AL
+
stop
=
00025
In
example 2
input should be carried out as follows
(input for the function is described below):
In posiiton #32 it is possible to output one or more functions for forms which have caused a
r
eading error
. The
function “select” is recommended, if there is a def lector unit available. The "Code" column in line 32 is here always
00000. In the "Function" column one or more functions can now be entered (as in numbers #00 - #31). See also
the function tables. If a read error occurs, i.e. none of the codes in #00 - #31 is recognised as valid, then the
function given in line #32 will be output for the form which caused the reading error. The machine will be stopped
and “read error” will appear in the display.
Suggestion for function in line #32:
Deflector unit 1 = 5-digit number 00004
The 5-digit number for the code remains 00000
3.3.2.3 Entering the 5-digit number for the functions
We shall now allocate a
function
to the marks on the form which are to be detected by the reading head.
Table 2 (page 35) for converting functions (Fnc) into 5-digit numbers is used in the same way as Table 1.
Each combination of marks represents one or more functions. To go back to our examples, we have here s ix
different functions (enveloping, collector, deflector unit 1, deflector unit 2, deflector unit 3 and s top).
Müller online
machines have fixed functions!
Input for the function is described in the examples above.
Содержание 6609
Страница 1: ...Braillo Cut Operating Instructions Automatic Forms Cutter Model 6609d 6612d Release 12 12 2006 ...
Страница 4: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 4 ...
Страница 35: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 35 OMR data list ...
Страница 40: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 40 OMR data list ...
Страница 53: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 53 4 4 1 Connections and electrical settings ...