Mod. 6609d-6612d:
Automatic Forms Cutter
13.12.2006
-50-
4.2 Troubleshooting
Problem
Causes and Solution
Machine always runs in reverse on
starting
Forms cutter does not stop at end
of paper
End-of-paper light barrier is covered by paper-holder.
End of paper cannot be detected, Adjust the paper-holder vertically
downwards. The light barrier must not be covered.
Light barrier is covered with paper dust and end of paper cannot be
detected. Clean the light barrier.
The height of the light barrier has been altered. End of paper cannot be
detected. Inform the service technician.
Forms are not cut straight
Inform the service technician.
Forms are not cut
Check the cut width factor (NO CUT means edge cut only)
Programs cannot be copied
You are not in the progra mming level (see Section 3.3)
Service routines cannot be called
Check whether you are in the technician level. For further information,
see Section 3.4.
Machine stops without any
message
Form is not being called by other equipment connected to the form
cutter.
The equipment is out of order, is not properly connected or is set at
Stop
.
Check the equipment.
Display messages:
see Section 3.1.3, page 14
Read errors:
see Section 3.3.2, page 29
Содержание 6609
Страница 1: ...Braillo Cut Operating Instructions Automatic Forms Cutter Model 6609d 6612d Release 12 12 2006 ...
Страница 4: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 4 ...
Страница 35: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 35 OMR data list ...
Страница 40: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 40 OMR data list ...
Страница 53: ...Mod 6609d 6612d Automatic Forms Cutter 13 12 2006 53 4 4 1 Connections and electrical settings ...