3.3.1.2 Parameter f)
Speed
In the
Speed
parameter the feed rate can be altered from level 1-7
(level 7 = maximum speed).
F4
- Press Input
The speed can also be changed during continous
operation. The change will automatically be saved in
the current programm.
F1
and
F2
- Select level 1-7
F4
- Exit
3.3.1.3 Parameter g)
Pause
In the
Pause
parameter seven different pause intervals (after cutting) can be preset.
The shortest interval is level 1 = 0,03 sec; longest interval is level 7 = 0.21 sec.
F4
- Press Input
The pause interval can also be changed during
continous operation. The change will automatically be
saved in the current program.
F1
and
F2
- Select level 0-7
F4
- Exit