![MTU 20V4000Bx4 Скачать руководство пользователя страница 172](http://html1.mh-extra.com/html/mtu/20v4000bx4/20v4000bx4_operating-instructions-manual_1852701172.webp)
1048 – AL Inj. Drift Limit 1 Cyl. B7
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B7 has violated limit 1.
The injector will soon reach its
maximum drift limit.
u
Schedule an injector replacement.
1049 – AL Inj. Drift Limit 1 Cyl. B8
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B8 has violated limit
value 1. The injector will soon
reach its maximum drift limit.
u
Schedule an injector replacement.
1050 – AL Inj. Drift Limit 1 Cyl. B9
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B9 has violated limit
value 1. The injector will soon
reach its maximum drift limit.
u
Schedule an injector replacement.
1051 – AL Inj. Drift Limit 1 Cyl. B10
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B10 has violated limit
1. The injector will soon reach its
maximum drift limit.
u
Schedule an injector replacement.
1052 – AL Inj. Drift Limit 2 Cyl. A1
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A1 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 196).
1053 – AL Inj. Drift Limit 2 Cyl. A2
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A2 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 196).
170 | Troubleshooting | MS15039/01E 2018-11
TIM-ID: 0000082405 - 002