![MTF DP C10 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/mtf/dp-c10/dp-c10_instructions-manual_1851981015.webp)
EN - 15
◆
Battery Power Bar Settings
Set Voltage represents voltage value settings. Each bar represents a voltage value. 5 bars voltage
values must be entered one by one. For example, VOL 1 is first bar voltage value. The default
value is 31.5V.
To set battery power bar, press the or the button to increase or decrease the number. To
store a changed setting and access the second bar, press
button.
In the same manner, after 5
bars voltage values are entered, hold the button to confirm and then return to the previous menu.
Battery bar settings interface
◆
AL sensitivity
Sensitivity represents Ambient Light Sensor settings. The sensitivity value ranges from 1 to 5. The
default value is 3. It can help with adjusting the screen brightness as per the ambient light
conditions automatically. When you ride the bike at night or in a place where there is a lack of light,
the display backlight and bike headlight will be turned on automatically.
Press Sensitivity and press / button to choose the desired sensitivity value.
Sensitivity settings interface
Advanced Settings
After General Settings (DisPlay Setting) is done, Press Back to return Setting page.
Press or button to choose Advanced Settings and press button to enter Advanced Settings
page.
◆
Controller Over-current Cut Settings
In the user settings, this function is disabled, and the settings are password protected. Adjustments
may only be made by an authorized service center.
Current Limit settings interface.
◆
Power Assistant Sensor Settings
Assistant Num represents PAS sensitivity settings. The sensitivity value is “5” to
“24”.
To change the sensitivity of PAS settings, press or button to choose the desired sensitivity
values. To store a changed setting, press the
button.