![MRM LFP Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/mrm/lfp/lfp_quick-start-manual_1845903019.webp)
LFP Quick Start Guide
15
4.
Repeat step 3 for the head tilt and position (if on a rail), and for the
lens controls (focus, zoom, and iris as applicable).
Session summary
After you have initially set up the system for your particular camera lens
and preferences, subsequent sessions take less time to set up, especially if
you have not disconnected control cables or moved sites. For subsequent
sessions at the same site you typically need to do the following at the start
of every session.
1.
Attach the power cables to the head and LFP.
2.
Load the head (page 4).
3.
Zero the axes (page 10).
If you have moved sites you will need to connect the control cables before
the power cables, and then set new soft limits after you have zeroed the
axes (page 13).
Hint
You can turn off the limits for one or more axes. For example if you
have an Ulti-head or AFC head with slip rings and you want to make
use of the 360 degree pan capability, set
PAN SL
to
DISABLED
.
For the lens controls you only set the
MAX
limit, as the
MIN
limit will
have already been set to zero when you zeroed the axes.
For all axes,
MAX
must be greater (more positive) than
MIN
. If this is
not possible for a particular axis (for example, if focussing closer puts
that axis into negative values) then it means that the axis values are
increasing in the wrong direction for that axis, on your particular rig.