6 Commissioning
Maschinenfabrik Reinhausen GmbH 2020
118
4983703/01 EN
VACUTAP
®
VV-Ex
6.2.3 Transport with empty transformer tank
NOTICE
Damage to the on-load tap-changer!
The on-load tap-changer may be subject to oscillating movements during
transformer transportation if the transformer is transported without insulating
fluid and the on-load tap-changer oil compartment is transported with insu-
lating fluid. These oscillating movements can lead to damage to the on-load
tap-changer.
► Completely empty the oil compartment if the transformer is to be trans-
ported without insulating fluid.
► Preserve the oil compartment in the same way as the transformer (for ex-
ample by filling with N2).
6.2.3.1 Emptying oil compartment via pipe connection S
1. De-energize all auxiliary circuits (e.g tap-change supervisory device, pres-
sure relief device, pressure monitoring device).
2. With the stop-cock (slide valve) between oil conservator and oil compart-
ment open, open air-vent valve E1 on the on-load tap-changer head.
3. Discharge the gas from under the on-load tap-changer cover. Ensure suf-
ficient fresh air (e.g. in transformer cells and work tents) when doing so.
4. Once the gas has been discharged and the insulating fluid is flowing out
of the air-vent valve, close the air-vent valve and close the stop-cock be-
tween the oil conservator and oil compartment.
5. Open air-vent valve again and drain off approximately 5–10 liters of insu-
lating fluid via the pipe connection S until the area under the on-load tap-
changer head cover is free of insulating fluid.
6. Loosen 24 screws M10 / wrench size 17 with locking elements on the on-
load tap-changer head cover.
7. Remove on-load tap-changer head cover.
8. Extract insulating fluid via pipe connection S.
9. Open stop-cock between oil conservator and oil compartment.
ð
Insulating fluid flows out of the oil conservator into the oil compartment.
10. Extract insulating fluid via pipe connection S.
11. Place on-load tap-changer head cover on the on-load tap-changer head.
12. Screw down on-load tap-changer head cover using 24 screws M10 /
wrench size 17 and locking elements (tightening torque 34 Nm).
Содержание VACUTAP VV-Ex
Страница 1: ...On load tap changer VACUTAP VV Ex Installation and commissioning instructions 4983703 01 EN ...
Страница 135: ...9 Drawings Maschinenfabrik Reinhausen GmbH 2020 135 4983703 01 EN VACUTAP VV Ex 9 Drawings 9 1 External view 737774 ...
Страница 138: ...9 Drawings Maschinenfabrik Reinhausen GmbH 2020 138 4983703 01 EN VACUTAP VV Ex 9 4 Installation drawing 738902 ...
Страница 139: ...9 Drawings Maschinenfabrik Reinhausen GmbH 2020 139 4983703 01 EN VACUTAP VV Ex 9 5 Oil suction pipe 739172 ...
Страница 142: ...9 Drawings Maschinenfabrik Reinhausen GmbH 2020 142 4983703 01 EN VACUTAP VV Ex 9 8 Mounting drawing 898866 ...
Страница 149: ......