Troubleshooting
Troubleshooting
Condition
Cause
Solution
Dishwasher will not run.
Low or no water.
Chemicals won’t feed into
dishwasher.
Door not closed.
Main power OFF.
Dishwasher OFF.
Circuit board fuse blown.
Main water supply off.
Fill hose kinked.
Low incoming water pressure
Solenoid valve defective.
Solenoid strainer clogged.
Chemical supply low.
Supply tubing damaged.
Supply tubing kinked.
Pick-up tube clogged
Chemical circuit board fuse blown.
Pump squeeze tube defective.
Close door completely.
Check breaker on panel.
Turn dishwasher power switch ON.
Contact service agent.
Open supply valve.
Straighten fill hose.
Set flowing water pressure to 25-95 PSI.
Install repair kit or replace.
Clean strainer.
Refill chemical container.
Replace tubing.
Straighten tubing.
Clean/replace tube.
Contact service agent.
Replace squeeze tube.
Low water pressure
pumped from wash spray
arms.
Clogged scrap screen.
Clogged spray arms.
Clogged pump intake.
Clean scrap screen.
Clean spray arms.
Inspect sump and clean pump intake.
Dishwasher stays in
wash cycle.
Rinse Sentry extends wash mode
for a maximum time of 5-minutes
to allow final rinse water booster
temperature to reach 180˚F/82˚C.
Contact service agent.
Poor wash results.
Excessively hard water.
Thermistor defective.
(See chemicals won’t feed
above.)
(See low or no water above.)
Detergent injector defective.
Chemical circuit board fuse blown.
Wares incorrectly loaded.
in dishrack.
Booster high limit tripped.
Wash tank high limit tripped.
Rinse arm nozzles clogged.
Contact chemical supplier.
Replace thermistor.
(See chemicals won’t feed
above.)
(See low or no water above.)
Replace squeeze tube.
Replace injector motor.
Clean tubing and pick-up.
Contact service agent.
Reposition wares or reduce amount of
wares in dish racks.
Reset or replace high limit.
Reset or replace high limit.
Clean nozzles with small paper clip.
Water has drained out of
the wash tank while the
dishwasher was idle.
Anti-siphoning loop in drain
hose has been removed.
Drain hose was extended.
Drain hose clamp is not
holding the drain hose
in proper position.
Building plumbing does not
provide correct air vent
to prevent siphoning.
Re-route drain hose.
DO NOT STRETCH HOSE
Replace/adjust hose clamp
making sure goose-neck
is maintained.
Contact service Agent
and/or plumber.
Содержание 601HTG
Страница 10: ...vi Blank Page This Page Intentionally Left Blank...
Страница 41: ...31 Blank Page This Page Intentionally Left Blank...
Страница 68: ...58 Digital Temperature Display Board...
Страница 69: ...59 601HTG Electrical Schematic SINGLE PHASE THREE PHASE...
Страница 70: ...60 601LTG Electrical Schematic...
Страница 71: ...61 601HTG 601LTG Timing Charts 601HTG 601LTG UL130...
Страница 72: ...62 This Page Intentionally Left Blank Blank Page...
Страница 74: ...64 Wash Pump Motor Assembly All Models 1 11 12 2 3 4 5 7 8 9 10 6 13 14 15...
Страница 79: ...69 69 Blank Page This Page Intentionally Left Blank...
Страница 82: ...72 Fill Solenoid Valve 601LTG 1 2 3 4 9 5 6 7 8...
Страница 86: ...76 Upper Final Rinse Piping 601HTG 1 2 4 5 7 8 9 4 8 11 14 16 17 18 6 3 15 6 6 22 22 10 20 23 23 12 13 19...
Страница 88: ...78 Fill Chute Assembly 601LTG 21 2 3 5 11 12 13 14 15 16 18 19 20 10 9 8 4 6 1 7 17 17 17 17...
Страница 94: ...84 Booster Assembly 601HTG 1 1 2 2 3 4 1 6 5 7 8 9 10 11 12 13 4 15 14...
Страница 96: ...86 Power Input Block and Cord Assemblies All Models 1 8 2 3 4 5 6 7 11 10 9 12 13 14 15 601LTG 601HTG 16...
Страница 98: ...88 Timer Control Board Assembly 601HTG Rear View Front View 1 10 2 4 4 5 6 2 4 7 8 9 11 12 13 3...
Страница 104: ...94 Control Panel 601HTG 10 11 12 13 14 3 2 1 4 5 6 7 9 8 8 9...
Страница 106: ...96 Control Panel 601LTG 3 12 12 10 9 9 8 7 11 2 4 5 6 1...
Страница 108: ...98 Panels All Models 1 10 2 3 4 6 5 7 8 9 11 12 13 13 14 15 16...
Страница 110: ...100 Door Assembly All Models 1 3 4 6 6 7 7 8 8 9 3 2 5...
Страница 112: ...102 Dish Racks Line Strainer PRV 1 2 3 4...
Страница 114: ...104 104 This Page Intentionally Left Blank Blank Page...