NPort 9000 Series CLI
Commands
2-52
2.3.1.4
trunk-mode
Use the
trunk-mode
interface configuration command on the device server to set the trunk mode of the
specified trunk group. Use the
no
form of this command to return to the default setting.
Commands
trunk-mode { static | lacp }
no trunk-mode
Syntax
Description
trunk-mode
Trunk mode configuration
static
Configure as static trunk
lacp
Configure as LACP trunk
Defaults
The default trunk mode of creating trunk manually is static.
Permission
Admin group
Usage
Guidelines
N/A
Examples
NPORT S9650I-16-2HV(config-if)# trunk-mode static
2.3.1.5
shutdown
To disable an interface, use the
shutdown
interface configuration command. To restart a disabled interface,
use the
no
form of this command.
Commands
shutdown
no shutdown
Syntax
Description
shutdown
Shutdown the selected interface
Defaults
N/A
Permission
Admin group
Usage
Guidelines
N/A
Examples
NPORT S9650I-16-2HV(config-if)# shutdown
NPORT S9650I-16-2HV(config-if)# no shutdown
2.3.1.6
name
Use the
name
interface configuration command to configure the interface name. To remove the configuration,
use the
no
form of this command.
Commands
name
no name
Syntax
Description
name
Port name
Defaults
N/A
Permission
Admin group
Usage
Guidelines
N/A
Examples
NPORT S9650I-16-2HV(config)# interface ethernet 1/1
NPORT S9650I-16-2HV(config-if)# name interface1_port1
NPORT S9650I-16-2HV(config-if)# no name