4) Min. Angle Control for Fastening Quality monitorin
g
Number
Unit
Range
Initial
P21~28
0.1 turn
0 ~ 30.0
0
Description
Minimum angle can be set as a threshold point for fastening quality
control by different setting on P78
.
"0" : No use "0.1~30.0" : Value of rotating angle (turn
)
P78 Min angle control setting should be one of below
0 : No use
1 : No torque up after Min angle on P78 - Er330
2 : Torque up before Min angle on P78 - Er331
3 : Both (1+2)
If the driver stops without torque up after the min angle, it provides
fastening NG output signal with the error code E330.
It is the most serious mistake by operator which is often found but
difficult to be recognized.
.
If the driver stops without torque up before the preset turn, it does not
provide fastening NG. Because it is very common operating together
with screw feeder.
If the driver stops with torque up before the min angle,
it provides fastening NG output signal with the error code E331
.
It is useful to detect the wrong aligned, engaged screw or
floating screws
.
1080 N 11th St - San Jose CA 95112 - mountztorque.com
26
Содержание SDC-24
Страница 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Страница 14: ...Straight Type SDA120 FV SDA200 FV SDA300 FV 1080 N 11th St San Jose CA 95112 mountztorque com 14...
Страница 16: ...Manual Hand Held Type SD05N SD09N SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 16...
Страница 61: ...7 12 25PIN I O Timing Chart 1 Fastening OK 2 Fastening NG 1080 N 11th St San Jose CA 95112 mountztorque com 61...
Страница 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Страница 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...