7.10 Preset Number Selecting by 25P I/O Port
The 25P I/O port is useful interface with the PLC. The PLC can select one of the 8
preset numbers through 3 pins. It cannot be used together with the direct sensor port.
For selecting a parameter using 25P I/O port, choose "1", “3” or “5” on the parameter P20.
By binary coding with 3 pins (pin no.1,2 and 3) among 25 pins, it makes 1 to 8 decimal
preset number. The torque selecting code should be before the Start signal.
1) Binary coding with 3 pins
Preset no.
pin
③
pin
②
pin
①
pin
⑧
1
0
0
0
2
0
0
1
3
0
1
0
4
0
1
1
5
1
0
0
6
1
0
1
7
1
1
0
8
1
1
1
M
ulti A
0
1
Multi B
1
1
7.11 25 PIN I/O Configuration
The configuration of 25P I/O port is different by the setting on P64.
[ P20 Setting ]
"0" : Torque selector by Sensor
"1" : Remote control I/O for PLC
"2" : Torque selector by Sensor (Input) + Remote control I/O for PLC (Output)
1080 N 11th St - San Jose CA 95112 - mountztorque.com
54
Содержание SDC-24
Страница 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Страница 14: ...Straight Type SDA120 FV SDA200 FV SDA300 FV 1080 N 11th St San Jose CA 95112 mountztorque com 14...
Страница 16: ...Manual Hand Held Type SD05N SD09N SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 16...
Страница 61: ...7 12 25PIN I O Timing Chart 1 Fastening OK 2 Fastening NG 1080 N 11th St San Jose CA 95112 mountztorque com 61...
Страница 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Страница 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...