ACK
7) Driver LOCK (L)
Transmission
1 : This command performs a locking function to prevent the rotating an electric
screwdriver, such as, for emergency stop. If SDC power on again, this feature is
turned off.
2 : Data
( 0: Release lock, 1: Two-way lock, 2: Loosening lock, 3: Fastening lock )
STX
L
2 BCC
ETX
STX
ETX
Data (0 ~ 3)
PC
SDC
S
T1
T1 < 500 msec
T1 > 1 sec : time out