23) Converted Torque Limit
Number
Unit
Range
Initial
P59
%
0 ~ 25
0
Description
If the converted torque is over than the setting value(%), NG (Er 335)
will be displayed
"0" : No use
"
±25%" : +/- tolerance limit from target
24) Time Limit for Fastening, Loosening and Motor Stall
Number
Unit
Range
Initial
P60~62
0.1 sec
0 ~ 60
Description
It prevents the continuous running over the preset time in direction of
fastening and loosening for safety operation. The driver stops
automatically at the preset time and provides the pattern NG with the
error code below;
P60 : Limit of fastening run time error code - E300
P61 : Limit of loosening run time error code - E301
Initial value = 10.0 sec
Also it prevents the continuous time going against the motor stall for
over heat protection.
P62 : Limit of motor stall time error code - E304
Initial value = 1.0 sec
25) Error Display Time Setting
Number
Unit
Range
Initial
P74
sec
0 ~ 10.0
1
Description
Error displays and resets after the below set time.
"0" : Manual reset by RESET button
"0.1 ~10.0 sec" : Auto reset after set time
1080 N 11th St - San Jose CA 95112 - mountztorque.com
39
Содержание SDC-24
Страница 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Страница 14: ...Straight Type SDA120 FV SDA200 FV SDA300 FV 1080 N 11th St San Jose CA 95112 mountztorque com 14...
Страница 16: ...Manual Hand Held Type SD05N SD09N SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 16...
Страница 61: ...7 12 25PIN I O Timing Chart 1 Fastening OK 2 Fastening NG 1080 N 11th St San Jose CA 95112 mountztorque com 61...
Страница 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Страница 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...