7.7 Error Code
1) System Error
code
Error
Description
How to reset
110 AD offset error
When the power of controller is ON,
the current offset is out of range.
Reset and retry booting.
If failed, repair is required
RESET button
111 SMPS Fault by
overload
Overload protection over 8A on SMPS
power supply circuit.
Power Off →On
after 1 min.
112 Over speed
Over rotation speed than the set value.
Check the cable connection.
Auto reset
after 1 sec.
113 Communication
error
Communication error during connected
Power Off →On
114
Screwdriver
recognition
error
Controller cannot recognize the connected
screwdriver.
Power Off →On
115
Controller
recognition
error
Program itself cannot recognize the controller
information.
Power Off →On
118 No motor
rotation error
When motor rotation is not monitored.
RESET button
200 Parameter
reading failure
It failed to read parameter at all.
Check the EEP-ROM damage or
communication failure.
Power Off →On
201
Parameter
Checksum
error
The read parameter is wrong by the
checksum routine.
Power Off →On
220 Multi-seque
n
ce
program error Multi-sequence program is wrong.
RESET button
1080 N 11th St - San Jose CA 95112 - mountztorque.com
50
Содержание SDC-24
Страница 12: ...SD400 SD600 SD1000 SD1500 SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 12...
Страница 14: ...Straight Type SDA120 FV SDA200 FV SDA300 FV 1080 N 11th St San Jose CA 95112 mountztorque com 14...
Страница 16: ...Manual Hand Held Type SD05N SD09N SD18N SD28N 1080 N 11th St San Jose CA 95112 mountztorque com 16...
Страница 61: ...7 12 25PIN I O Timing Chart 1 Fastening OK 2 Fastening NG 1080 N 11th St San Jose CA 95112 mountztorque com 61...
Страница 69: ...2 Direct Wiring to 25P I O Interface Port 1080 N 11th St San Jose CA 95112 mountztorque com 69...
Страница 90: ...9 Screw Count Monitoring Single 1080 N 11th St San Jose CA 95112 mountztorque com 90...