26) Beep Sound ON/OFF
Number
Unit
Range
Initial
P77
0 or 1
1
Descr
i
p
tion
The beep sound can be off
0 : OFF 1 : ON
27) No Torque Complete Error
28) Fastening Complete Signal Out Time Setting
29) Reverse Lock Setting (Hand held driver only)
Number
Unit
Range
Initial
P91
0 ~ 1
1
Description
Enable/ Disable of Reverse rotation switch
0 : Disable 1 : Enable
Number
Unit
Range
Initial
P89
0 or 1
0
Description
If operator releases the trigger lever and stops operation of
screwdriver after screw seating point without completing cycle,
it gives an error alarm
E333
"0" : Disable "1" : Enable
Fastening process only
Number
Unit
Range
Initial
P90
0 or 500
0
Description
Fastening complete signal time set
Setting : 0 ~ 500 ms
( 0 = No use )