If the jog command is reset within the rising time of the ramp, the frequency is changed from the
current point and falls to zero. If a new jog command is set during the downward ramp, a jump to zero
is executed and then the new rising ramp is started. If the Special Mode parameter is set unequal to
zero, no jump to zero is executed but the new ramp rises at the current value.
The Jog Speed parameter can also be changed while motion. But this change manifests itself
abruptly.
This command is used together with Inhibit.
Tiggering Parameter
Comment
Addition
Input
Input X Config = 0/1
Input X Function = 4
If Input X Config = 0 is set, the command is
triggered in case of a "low" state at input X.
The status of the input can be
read in the OS Input field
Lecom
Code 59 (dec)
Release: 04 31 31 02 35 39 30 03 3F
Set: 04 31 31 02 35 39 31 03 3E
(Unit no. 11, command in hex)
If a 1 is written at code 59, the
command is set.
Modbus
FF08 (hex)
Release: 07 06 FF 08 00 00 38 7A
Set: 07 06 FF 08 00 01 F9 BA
(Modbus address = 7, command in hex)
If a 1 is written to FF08, the
command is set.
If the Output X Function parameter is set to 3, the output reflects the direction.
If the parameter Output X Function is set to 6, the output reflects the complete movement. (Frequency
> 0 or run, Output High without inversion)
Process Jog: Normal motion
Process Jog: Reset before Jog Speed is reached