Input Functions
Reset Static
The Reset Static function sets the frequency output to 0Hz independent of the frequency input.
This function also resets the commands for Reference and Jog.
Triggering Parameter
Comment
Addition
Input
Input X Config = 0/1
Input X Function = 11
If Input X Config = 0 is set, the command is
triggered in case of a "low" state at input X.
The status of the input can be
read in the OS Input field
Lecom
Code 54 (dec)
Release: 04 31 31 02 35 34 30 03 32
Set: 04 31 31 02 35 34 31 03 33
(Unit no. 11, command in hex)
If a 1 is written at code 54, the
command is set.
Modbus
FF02 (hex)
Release: 07 06 FF 02 00 00 18 78
Set: 07 06 FF 02 00 01 D9 B8
(Modbus address = 7, command in hex)
If a 1 is written to FF02, the
command is set.
If the Output X Function parameter is set to 4, the output reflects the command status.
(command set, output high without inversion)
Direction
The Direction function changes the direction of the frequency output.
Triggering Parameter
Comment
Addition
Input
Input X Config = 0/1
Input X Function = 3
If Input X Config = 0 is set, the command is
triggered in case of a "low" state at input X.
The status of the input can be
read in the OS Input field
Lecom
Code 58 (dec)
Release: 04 31 31 02 35 38 30 03 3E
Set: 04 31 31 02 35 38 31 03 3F
(Unit no. 11, command in hex)
If a 1 is written at code 58, the
command is set.
Modbus
FF00 (hex)
Release: 07 06 FF 00 00 00 B9 B8
Set: 07 06 FF 00 00 01 78 78
(Modbus address = 7, command in hex)
If a 1 is written to FF00, the
command is set.
If the Output X Function parameter is set to 3, the output reflects the direction.
(frequency > 0, output high without inversion)
This command can be used together with other commands.