Fm210_01b_oi_e.docx / Nov-20
Page 17 / 40
Serial Menu
Nr. Parameter
Adjustment range Default
042
USB Unit No.:
USB unit number for the virtual port is fixed to 11.
11
11
043
USB Baud Rate:
USB baud rate for the virtual port is fixed at 115.2 kBaud.
0
0
044
USB Baud Rate:
USB format for the virtual port is fixed to 8N1.
0
0
045
Serial Page:
Selection of a specific variable page for internal diagnostics
0 - 7
0
046
Serial Mode:
Switching the RS-485 interface to different protocols, baud rates and
formats
0 : Lecom protocol with RS Unit No., Baud rate and format
1 : Modbus protocol with RS baud rate and 8E1
2 : Modbus protocol with RS baud rate and 8O1
3 : Modbus protocol with RS baud rate and 8N2
0 - 3
0
047
RS Unit No.:
Unit No. for the RS-485 interface (only for Lecom protocol)
11 - 99
11
043
RS Baud Rate:
RS Baud rate for the RS-485 interface
0 : 9600 Baud
1: 4800 Baud
2: 2400 Baud
3: 1200 Baud
4: 600 Baud
5: 19200 Baud
6: 38400 Baud
7: 56000 Baud
8: 57600 Baud
9: 76800 Baud
10: 115200 Baud
0 - 10
10
044
RS Format:
Format for the RS-485 interface
0 : 8N1 (8 data bit, non-parity, 1 stop bit)
1 : 8E1 (8 data bit, even parity, 1 stop bit)
2 : 8O1 (8 data bits, odd parity, 1 stop bit)
0 - 2
0
045 Reserved
046 Reserved