Output Menu
Nr. Parameter
Adjustment range Default
033
Output 1 Function:
0: No function
1: Encoder input error (only with input format RS-422 or
HTL differential)
2: Phase error (parameter Diff Error exceeded)
3: Fout > 0 (Direction recognition)
4: Reset activated
5: Reference activated
6: Jog activated
7: Encoder input error and phase error
(parameter Diff Error exceeded)
0 - 7
1
034
Output 2 Function:
see Output 1 Function
0 - 7
1
035
Output Polarity:
Switching the output polarity (binary)
0: no inversion of the outputs
1: OUT1 inverted, OUT2 not inverted
2: OUT1 not inverted, OU2 inverted
3: both outputs are inverted
0 - 3
0
036
Diff Error:
Number of differential counter increments at which the phase error is
activated for the outputs. With a setting of 50, a phase error is
triggered when the differential counter increments rise above 50 or
falls below -50.
0 - 99999
64
037 Reserved
Modbus Menu
Nr. Parameter
Adjustment range Default
038
Modbus Address:
Modbus address
1 - 247
1
039
Modbus CRC Reset:
Modbus CRC Calculator Reset
Additional tool, serves to calculate the CRC value
0 - 1
0
040
Modbus CRC Byte:
Modbus CRC Calculator Byte
Additional tool, serves to calculate the CRC value
0 - 255
0
041 Reserved