By340_04b_oi_e.doc / Apr-16
Page 27 / 42
8.2.5.
Analog output definitions
F05
Range
Default
F05.038 Control characteristics and analog format
0 … 3
0
0= The slave speed changes proportionally to the
Factor 1 setting, i.e. doubles motor speed when
changing Factor 1 from 1.00000 to 2.00000.
(suitable for most of all applications)
Output scaled for a -10 volts … +10 volts signal
1= The slave speed is reciprocal to the Factor 1
setting, i.e. halves the motor speed when
changing Factor 1 from 1.00000 to 2.00000.
(suitable for rotating cutter applications when
Factor 1 represents the length preset)
Output scaled for a -10 volts … +10 volts signal
2= Similar to setting 0, but
Output scaled for a -20 mA … +20 mA signal
3= Similar to setting 1, but
Output scaled for a -20 mA … +20 mA signal
F05.039 Offset Correction:
Digital setting of analog offset on correction signal.
-10.000 … +10.000
(volts)
0.000
F05.040 Gain Correction:
Digital setting of the proportional gain of the control
loop. Setting to 2.048 results in a response of 1 mV
per error bit. Recommended setting: 0.500...5.000
(Gain Correction / 2048 = x.xxx volts per error bit).
0 … 51.200
2.000
F05.041 Max. Correction:
Limitation of the output voltage of the correction
signal (correction will not exceed this setting)
0 … 10.000
(volts)
2.000
F05.042 Offset Total:
Digital setting of analog offset of the overall analog
output signal.
-10.000 … +10.000
(volts)
0.000
F05.043 Gain Total:
Sets the full-scale output voltage at maximum master
frequency.
0 … 99.999
10.000
n. a. = not applicable
Calculation of analog output voltage:
ection
OffsetCorr
tion
GainCorrec
counter
al
Differenti
l
OffsetTota
uency
MasterFreq
Max
frequency
master
Factor
GainTotal
V
U
A
2048
.
1
]
[
Feed forward signal
correction signal