By340_04b_oi_e.doc / Apr-16
Page 14 / 42
Please observe the minimum duration of 50 µs. for index pulses
Every index pulse must clearly mark one explicit and repeatable event
within one machine cycle
6.
Operating Modes
The operating mode (parameter F02.004) sets the functions of Trim and Index inputs, provided
that these functions have been assigned to some Control Inputs or front keys.
Mode
F02.004
Trim Input Function
Index Input Function
Impulse scaling
(Slave : Master)
1
+/- Phase trim by internal
timer. Temporary change of
Slave speed while one of
the Trim commands is on.
No Function
Fact 1 : Fact 2
2
Similar to Mode 1
Index control with adjustable phase
Fact 1 : 1.00000
Adjustable Phase Offset
Index Master
Index Slave
3
Similar to Mode 1
Index Master: Slave jumps forward
Index Slave: Slave jumps reverse
Fact 1 : Fact 2
Slave position before index signal
Slave position after index signal
Jump (Offset)
4
Similar to Mode 1
Motor Potentiometer Function:
Index Master: Increment Factor1 (+++)
Index Slave: Decrement Factor1 (---)
Fact 1 : Fact 2
5
Phase trim by external pulse
source
No Function
Fact 1 : Fact 2
6
Phase trim by external pulse
source
Similar to Mode 2
Fact 1 : 1.00000
7
Similar to Mode 1
Similar to Mode 1
Fact 1 : Fact 2
8
Similar to Mode 1
Unlocked index operation with soft
correction, for use with special
applications like gantry cranes or
precision register control.
Fact 1 : 1.00000