Installation Quickstart
– continued
DRAFT
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
Apr 2001
V0C.03
138
Tools and Hardware
– Wire Cutters
– 110 style Punch Block Punch Tool
(CGDS237176)
– 10 mm Socket
– Tin Snips
– Crimp Tool for Compression Lug
(CDGSTBM25S)
– Drill Motor
– 18 mm (11/16”) Masonry Drill bit
– Torque Driver (NOTE: Torque range is from 5 to
135 N–m (from 4 to 100 ft–lbs)
– 19 mm (3/4”) Open Ended Torque Wrench (for
N–type connector)
– Thomas & Betts TBM14 Hydraulic crimping
tool with color keyed crimp die set (or
equivalent)
– 19 mm (3/4”) Deep Socket
Site Considerations
A quick reference of specific site considerations is shown in Table C-1.
Table C-1: Site Considerations
n
Site Consideration
References and Recommendations
Clearances around BTS
See chapter 1 in the manual for figures.
Power Cabinet: Front = 45” Back = 26” Left Side = 5” Right Side = 13”
RF Cabinet: Front = 45” Back = 20” Left Side = 10” Right Side = 5”
Adequate Ventilation
(Indoor Unit Only)
Ventilation to dissipate heat loads of 7,500 W (25,600 Btu/hr) for the RF
Cabinet, and 3,000 W (10,300 Btu/hr) for the Power Cabinet (a total of
10,500 Watts; 35,900 Btu/hr).
Maximum Ambient Temperature of 50 Deg C (122 Deg F)
Location
Locations should be selected to minimize accidental or intentional
vandalism, and not be subject to submersion or potential flooding.
Adequate clearance through door and passageways to allow movement of
the cabinet.
Rooftop installation
SC 4812ET RF Cabinet maximum weight = 680 kg. (1500 lbs.)
SC 4812ET Power Cabinet maximum weight = 1580 kg. (3500 lbs.)
Ensure that all loading & zoning requirements have been approved
BTS Mounting holes
drilled
See Chapter 2 – “Drilling Procedures”
AC Power Pedestal or
Meter Provided
Recommended power pedestal breaker rated @ 150Amps for one BTS, or
per Local Electrical Code.
AC Power Supplied to
site
See Chapter 2, “Materials Needed” BTS rated @ 130A (208–240VAC)
Alarm and Span Line
Cable Equipment
Available
Twenty–five (25) twisted pair cable, 1” watertight conduit
Ground Wire Connection
Supplied
Motorola recommends #3 BSWG (#2 AWG) solid–tinned wire.
. . . continued on next page
C