Cabinet Cabling
– continued
Apr 2001
V05.03
117
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
DRAFT
Table 5-32: Power Cabinet AC Current Requirements
Number of Sector–Carriers
1
Power Cabinet AC Current
Ratings
2
Number of Rectifiers
12
6
100A (130A Non–Continuous)
1
To obtain this number multiply the number of sectors by the number of carriers (i.e., 6 sector, 2 carrier = 12
sector–carrier).
2
30A Non–continuous is for the GFCI outlets and the 15A Spare Breaker in the Power Cabinet
Heat Dissipation
The minimum heat dissipated to prevent condensation
inside the cabinet under the extremes of environmental
conditions is 110 Watts for the RF Cabinet and 110 Watts
for the Power Cabinet. This can be accomplished by
following the Initial Power Up procedures in the SC
4812ET ATP manual.