Release 1.0
Configuring the CMTS
526360-001-00 Rev. B
MGBI
6-95
MOT(config-if)#
cable privacy cm-tek reset
[
<1-16383>
]
where:
1-16383
is the primary Service Identifier (SID) of the cable modem.
4.
The default lifetime TEK is 43,200 seconds. Use the
cable privacy cm-tek
life-time
command to set a lifetime TEK for an individual CM in Interface
Configuration mode:
MOT(config-if)#
cable privacy cm-tek life-time
<
0-16383
>
<
1800-604800>
where:
0-16383
is the CM’s primary SID.
1800-604800
is the TEK lifetime value, expressed in seconds
.
5.
Use the
show cable privacy tek
command in Interface Configuration mode to
display current TEK lifetime and grace-time information:
MOT#
show cable privacy tek
6.
Use the
show cable privacy cm-tek command
in Interface Configuration mode
to display TEK information for an individual CM using its MAC address:
MOT(config)#
show cable privacy cm-tek
[<
1-8192
>]
where:
1-8192
is the Service Identifier (SID)
.
Setting Authorization Key Values
An Authorization Key (AK) has a limited lifetime and must be periodically refreshed.
A CM refreshes its AK by re-issuing an Authorization Request to the cable interface.
Follow the steps in this section to configure the AK values.
1.
Use the
cable privacy cm-auth life-time
command in Interface Configuration
mode to set the AK lifetime value:
MOT(config-if)#
cable privacy cm-auth life-time
{<
mac
>}
[<
300-6048000> | <cr>
]
where:
mac
is the CM MAC address.
300-6048000
is the AK lifetime value, expressed in seconds
.
Содержание BSR 2000
Страница 1: ...BSR 2000 Configuration and Management Guide 526360 001 00 Rev B Release 1 0 MGBI ...
Страница 6: ... Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola ...
Страница 50: ......
Страница 130: ......
Страница 164: ......
Страница 458: ......
Страница 490: ......
Страница 580: ......
Страница 632: ......
Страница 648: ......
Страница 649: ......
Страница 650: ...526360 001 00 Rev B 7 06 MGBI Visit our website at www motorola com ...