Release 1.0
Configuring the System
526360-001-00 Rev. B
MGBI
3-13
Controlling Telnet and Console Access
Follow these steps to configure telnet and console access to the BSR:
1.
The default time-out value for a telnet session is five minutes. Use the
session-timeout telnet
command in Global Configuration mode to configure the
amount of time (retroactively) that telnet sessions can stay connected to the BSR:
MOT(config)#
session-timeout telnet
<
0-30
>
where:
0-30
is the telnet session limit in minutes.
2.
The default timeout value for a console session is five minutes. Use the
session-timeout console
command in Global Configuration mode to configure
the amount of time (retroactively) that console sessions can stay connected to the
BSR:
MOT(config)#
session-timeout console
<
0-30
>
where:
0-30
is the console session limit in minutes.
Note:
Setting the telnet session timeout to 0 allows telnet sessions to be
connected indefinitely.
Note:
The default console session timeout setting is 0, which causes the
console sessions to be connected indefinitely. If you do not want console
sessions to be connected indefinitely, for security or other reasons, specify a
value other than 0 using the
session-timeout console
command.
Содержание BSR 2000
Страница 1: ...BSR 2000 Configuration and Management Guide 526360 001 00 Rev B Release 1 0 MGBI ...
Страница 6: ... Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola ...
Страница 50: ......
Страница 130: ......
Страница 164: ......
Страница 458: ......
Страница 490: ......
Страница 580: ......
Страница 632: ......
Страница 648: ......
Страница 649: ......
Страница 650: ...526360 001 00 Rev B 7 06 MGBI Visit our website at www motorola com ...